{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1346-7FP13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1346-7FP13","canonicalUrl":"https://aoctrl.com/siemens/5SU1346-7FP13","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1346-7FP13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1346-7FP13 RCBO, 4-pole, 13 A rated, C tripping characteristic, 30 mA Type A residual current, 6 kA breaking capacity per EN 60898, 4 MW width, IP20.","salesMarkdown":"## Siemens SENTRON 5SU1346-7FP13 — 4-pole RCBO, 13 A C-curve, 30 mA Type A The 4 MW (72 mm) width and IP20 finger-safe terminals mean it snaps into a standard 4-module DIN-rail slot in a consumer unit or panelboard. At 13 A rated current, the RCBO handles continuous loads up to that value; derate per the temperature table: 12.2 A at 40 °C, 11.7 A at 45 °C, 11.2 A at 50 °C, 10.8 A at 55 °C, and 10.3 A at 60 °C ambient. Type A residual current detection covers pulsating DC fault currents from rectified loads (SMPS, LED drivers, VFDs) in addition to sinusoidal AC — important for modern panels with electronic loads. The 4 kV rated surge voltage withstand confirms coordination with standard SPDs at the service entrance. Supply can enter from either top or bottom, and mounting position is unrestricted — install it in any orientation within the distribution board. The IP20 protection rating applies when the board is installed with conductors connected; the enclosure itself provides the additional ingress protection for the panel environment. Depth is 72 mm, installation depth 70 mm, height 85 mm — fits standard 4-module cutouts in consumer units and panelboards.","metaTitle":"Siemens SENTRON 5SU1346-7FP13 RCBO, 4P C13 30mA Type A, 6kA","metaDescription":"Siemens SENTRON 5SU1346-7FP13 RCBO, 4-pole, 13 A, C-curve, 30 mA Type A residual current, 6 kA breaking capacity per EN 60898. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"72 mm","Width":"72 mm","title":"5SU1346-7FP13","Height":"85 mm","Maximum":"70 °C","Minimum":"-40 °C","description":"RCBO, 6 kA, 4P Type A, 30 mA, C-Char, In: 13A Un: 400V","Halogen-Free":"No","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"13 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Weight With Packaging":"550 g","at 30 °C rated value":"13 A","at 40 °C rated value":"12.2 A","at 45 °C rated value":"11.7 A","at 50 °C rated value":"11.2 A","at 55 °C rated value":"10.8 A","at 60 °C rated value":"10.3 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"4","according to EN 60898 rated value":"6 kA","Tripping Fault Current Rated Value":"30 mA","insulation voltage (Ui) rated value":"500 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"6 kA","Surge Current Resistance At (8/20) μS":"0.25 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6e2e6ddacb60a42cb10c149ae3a30b8e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1438060&mlfb=5SU1346-7FP13"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SU1346-7FP13?","answer":"It is rated 6 kA per both EN 60898 and IEC 60947-2, suitable for final circuits in residential and light commercial distribution boards."},{"question":"What does Type A residual current mean on this RCBO?","answer":"Type A detects pulsating DC fault currents from rectified loads (SMPS, LED drivers, VFDs) in addition to sinusoidal AC, covering modern electronic loads in the circuit."},{"question":"What is the temperature derating for 5SU1346-7FP13?","answer":"Rated 13 A at 30 °C, derated to 12.2 A at 40 °C, 11.7 A at 45 °C, 11.2 A at 50 °C, 10.8 A at 55 °C, and 10.3 A at 60 °C ambient."},{"question":"Where can I buy 5SU1346-7FP13 and what is the lead time?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1346-7FP13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1346-7FP13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}