{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-0KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-0KK13","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-0KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-0KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole, 13 A rated, Type B tripping characteristic, Type AC residual current, 10 kA (EN 60898) / 20 kA (IEC 60947-2) breaking capacity, instantaneous design, IP20 with distribution board installed.","salesMarkdown":"## Siemens 5SU1354-0KK13 — SENTRON RCBO, 13 A, Type B, Type AC Residual Current Breaking capacity is 10 kA per EN 60898 and 20 kA per IEC 60947-2, giving it headroom above the standard domestic 6 kA requirement — useful for industrial sub-distribution where fault levels are higher. The Type AC residual current detection handles sinusoidal AC fault currents; for pulsed DC or smooth DC faults you'd need a Type A or F device. Rated current derates with ambient temperature: 13 A at 30 °C, 12.48 A at 40 °C, 11.96 A at 50 °C, 10.53 A at 65 °C, and 10.01 A at 70 °C. If the panel runs hot (common in crowded enclosures), the effective rating drops — factor that into your load calculation. Supply can enter from top or bottom, and mounting position is any orientation — no derating for sideways or inverted mounting. ## Panel Integration The 36 mm width (2 MW) matches the standard SENTRON grid; depth of 77 mm and installation depth of 70 mm mean it sits flush in a 4-row enclosure without hitting the gland plate. IP20 rating applies only with the distribution board installed and conductors connected — it's not a standalone IP20 device for open-panel use.","metaTitle":"Siemens 5SU1354-0KK13 SENTRON RCBO, 13A, 10kA, Type B","metaDescription":"Siemens 5SU1354-0KK13 SENTRON RCBO, 2-pole, 13A rated, 10kA (EN 60898) / 20kA (IEC 60947-2), Type B characteristic, Type AC residual current. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"13 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"281 g","at 30 °C / rated value":"13 A","at 40 °C / rated value":"12.48 A","at 45 °C / rated value":"12.22 A","at 50 °C / rated value":"11.96 A","at 55 °C / rated value":"11.57 A","at 60 °C / rated value":"11.31 A","at 65 °C / rated value":"10.53 A","at 70 °C / rated value":"10.01 A","Number Of Modular Width Units":"2","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"10 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"20 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d840d1727fca4cb59daff68e966913a9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=57629&mlfb=5SU1354-0KK13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-0KK13/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SU1354-0KK13?","answer":"The breaking capacity is 10 kA per EN 60898 and 20 kA per IEC 60947-2, giving it headroom above standard domestic 6 kA requirements for industrial sub-distribution."},{"question":"What temperature derating applies to 5SU1354-0KK13?","answer":"Rated current derates from 13 A at 30 °C to 10.01 A at 70 °C. The operating temperature range is -40 °C to 75 °C, so it handles cold outdoor cabinets but loses capacity in hot panels."},{"question":"Where can I buy 5SU1354-0KK13?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-0KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-0KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}