{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-0KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-0KK16","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-0KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-0KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1354-0KK16 RCBO, 16 A at 30 °C, Type B, 10 kA (EN 60898), 1P+N, 2 MW, IP20.","salesMarkdown":"## RCBO for final-circuit protection Type B tripping characteristic (3–5× In magnetic release) suits residential and light commercial final circuits where inrush from lighting or small electronics is moderate — not motor or transformer loads that need Type C or D. Current rating is temperature-dependent: 16 A at 30 °C, derated to 15.2 A at 40 °C, 14.4 A at 50 °C, and 12.32 A at 70 °C. In a warm enclosure (40–50 °C typical for a loaded panel), expect to apply the 40 °C or 50 °C column for continuous load sizing — not the 30 °C headline figure. The 1P+N design switches the line conductor only; the neutral is switched internally for isolation but not protected against overcurrent. That matches single-phase final circuits where the neutral is not overloaded. Mounting position any, supply feed from top or bottom — flexible for panel layout.","metaTitle":"Siemens 5SU1354-0KK16 SENTRON RCBO, 16A, 10kA, Type B, 1P+N","metaDescription":"Siemens SENTRON 5SU1354-0KK16 RCBO, 16A rated, 10 kA breaking capacity per EN 60898, Type B characteristic, 1P+N, 2-module width. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"277 g","at 30 °C rated value":"16 A","at 40 °C rated value":"15.2 A","at 45 °C rated value":"14.88 A","at 50 °C rated value":"14.4 A","at 55 °C rated value":"13.92 A","at 60 °C rated value":"13.6 A","at 65 °C rated value":"12.96 A","at 70 °C rated value":"12.32 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"10 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"20 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc761038274bf31fc4126ed314f68336.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=63855&mlfb=5SU1354-0KK16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-0KK16/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1354-0KK16 and how do I get a price?","answer":"This RCBO is sourced to order against an RFQ through independent distribution. Submit a request for a firm quote; availability and current pricing are confirmed at that time."},{"question":"What is the breaking capacity of 5SU1354-0KK16?","answer":"Rated 10 kA per EN 60898 and 20 kA per IEC 60947-2 — the higher figure applies when the device is used in industrial coordination studies under the product standard for circuit-breakers."},{"question":"Does 5SU1354-0KK16 drop into a panel built for 5SY4116-6CC?","answer":"Both are 2-module-wide (36 mm) DIN-rail devices, so the footprint matches. However, 5SU1354-0KK16 is a combined RCBO (MCB+RCD) while 5SY4116-6CC is a standalone MCB — the RCBO adds residual-current protection and requires a neutral connection. Rewiring is needed if the panel originally had a separate RCCB upstream."},{"question":"What compliance documentation does Siemens provide for 5SU1354-0KK16?","answer":"The device is halogen-free and silicon-free, rated IP20 in an installed distribution board. It is designed to EN 60898 and IEC 60947-2. Standard Siemens declarations (CE, UKCA) apply; specific RoHS/REACH statements are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-0KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-0KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}