{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-1KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-1KK13","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-1KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-1KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 13 A, 30 mA, Type C, 10/20 kA, 230/240 V AC, 50 Hz, 2 MW.","salesMarkdown":"## Siemens 5SU1354-1KK13 — SENTRON RCBO, 13 A, 30 mA, Type C The neutral pole is switched, and the supply can enter from either the top or bottom. This is a current-production part, actively quoted through independent distribution channels. The 30 mA residual sensitivity provides additional protection against electric shock for socket-outlet circuits and final subcircuits in residential and commercial installations. The 10 kA (EN 60898) / 20 kA (IEC 60947-2) prospective fault current ratings tell you the device can safely interrupt a short-circuit up to those levels — the higher IEC 60947-2 figure is the one that matters for industrial panel coordination. The 1P+N configuration switches both phase and neutral, with the neutral pole making and breaking; this is standard for single-phase final circuits where isolation of both conductors is required. At 2 modular width units (36 mm wide, 90 mm tall, 77 mm deep including terminals), the 5SU1354-1KK13 snaps onto a standard DIN rail and occupies two adjacent 18 mm slots in a distribution board. The installation depth is 70 mm. Mounting position is unrestricted, and the supply cable can enter from either top or bottom. The IP20 rating is typical for enclosed distribution boards — the touch protection feature is active once conductors are connected.","metaTitle":"Siemens 5SU1354-1KK13 SENTRON RCBO, 13 A, 30 mA, Type C, 1P+","metaDescription":"Siemens SENTRON 5SU1354-1KK13 RCBO, 13 A rated, 30 mA residual, Type C, 1P+N, 10 kA (EN 60898) / 20 kA (IEC 60947-2). Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230/240 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"286 g","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"10 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"20 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","operational current / at AC / rated value":"13 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7f875620496c2f22fc7d167e54595fcc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=333296&mlfb=5SU1354-1KK13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-1KK13/alternatives.json"},"ai":{"faq":[{"question":"What is the rated current and residual sensitivity of 5SU1354-1KK13?","answer":"It is rated 13 A with a 30 mA residual-current trip, Type C characteristic, for 230/240 V AC, 50 Hz single-phase circuits."},{"question":"What breaking capacity does 5SU1354-1KK13 have?","answer":"The breaking capacity is 10 kA per EN 60898 and 20 kA per IEC 60947-2, covering standard distribution-board fault levels."},{"question":"What is the physical size of 5SU1354-1KK13?","answer":"It is 36 mm wide (2 modular units), 90 mm tall, and 77 mm deep, with an installation depth of 70 mm. It snaps onto a standard DIN rail."},{"question":"Where can I buy 5SU1354-1KK13 and how is it quoted?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-1KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-1KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}