{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-3KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-3KK06","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-3KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-3KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1354-3KK06, RCBO, 1P+N, 6 A rated, Type F residual current 30 mA, tripping characteristic B, 10 kA breaking capacity per EN 60898, 2 MW.","salesMarkdown":"The Siemens 5SU1354-3KK06 is a SENTRON RCBO combining overcurrent protection (characteristic B, 6 A rated) with residual current detection (Type F, 30 mA trip threshold) in a single 2-module-wide (36 mm) package for 1P+N circuits. Type F residual current detection handles sinusoidal AC faults, pulsating DC faults, and composite faults up to 1 kHz — the standard for single-phase inverter-fed loads like washing machines, heat pumps, and LED drivers where Type A may nuisance-trip on high-frequency leakage. ## Temperature derating — the real continuous current ceiling The mounting position is unrestricted, but the derating curve assumes free convection — stacking in a sealed enclosure without ventilation shifts the effective ambient upward. ## Panel fit — 2 MW, 36 mm, any position IP20 with the distribution board installed and conductors connected — the RCBO itself is not sealed against washdown; it lives inside a cabinet. ## Lifecycle and sourcing — active production, quoted to order No stock-holding claim — each order is quoted to the buyer's required volume.","metaTitle":"Siemens 5SU1354-3KK06 SENTRON RCBO, 6A Type F 30mA, 10kA","metaDescription":"Siemens SENTRON 5SU1354-3KK06 RCBO, 1P+N, 6A rated, Type F residual current, 30mA trip, 10kA breaking capacity per EN 60898. Active production, sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","title":"5SU1354-3KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, 10 kA, 1P+N, type F, super-resistant K, 30 mA, B char., In: 6 A, Un AC: 230 V","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCBO","at AC / rated value":"6 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Super resistant K","Residual Current Type":"F","Energy Limitation Class":"3","Weight / With Packaging":"285 g","according to EN 61346-2":"F","at 30 °C / rated value":"6 A","at 40 °C / rated value":"5.7 A","at 45 °C / rated value":"5.58 A","at 50 °C / rated value":"5.4 A","at 55 °C / rated value":"5.22 A","at 60 °C / rated value":"5.1 A","at 65 °C / rated value":"4.86 A","at 70 °C / rated value":"4.62 A","according to IEC 81346-2":"F","Number Of Modular Width Units":"2","Tripping Characteristic Class":"B","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","according to EN 60898 / rated value":"10 kA","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","according to IEC 60947-2 / rated value":"35 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"3 kA","Type Of Voltage / Of The Operating Voltage":"AC","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$67.04","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/703375e28c426447188bb4ea5db5c90f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=520194&mlfb=5SU1354-3KK06"},"ai":{"faq":[{"question":"Can a 1P+N RCBO be used for single-phase load?","answer":"Yes — the 1P+N design switches the phase conductor and monitors the neutral for residual current, exactly matching a single-phase line-to-neutral circuit."},{"question":"How is 5SU1354-3KK06 quoted for volume purchases?","answer":"Quoted to order against the BOM quantity through independent distribution — availability and per-unit pricing are confirmed at RFQ time, with no minimum order quantity beyond the distributor's standard terms."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-3KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-3KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}