{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-4KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-4KK16","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-4KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-4KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SU1354-4KK16, 16 A, C-curve, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 2-pole 1P+N, super resistant K, -40…75 °C, IP20, 2 MW wide.","salesMarkdown":"## Siemens 5SU1354-4KK16 — SENTRON RCBO, 16 A C-curve, super resistant K This is the 'super resistant K' variant, designed for environments with aggressive atmospheres — think offshore platforms, chemical plants, or coastal turbine nacelles where standard RCBOs corrode within a season. It's halogen-free and silicon-free, so no outgassing issues in sealed enclosures. The thermal derating curve is published from 30 °C to 70 °C: 16 A at 30 °C, dropping to 12.32 A at 70 °C. That matters when you pack these into a crowded panel — you don't guess the de-rate; you read the line. Two modular-width units (36 mm wide) snap onto standard DIN rail. Depth is 77 mm, installation depth 70 mm — fits most distribution boards without a deep enclosure. IP20 rating applies only when the distribution board is installed with connected conductors — this is a panel-internal device, not for standalone outdoor use. The C-curve (tripping characteristic class C) means magnetic trip between 5 and 10 times In — 80 to 160 A for this 16 A unit. That's the standard choice for motor circuits, small transformers, and lighting with inrush. For residential or purely resistive loads, a B-curve would trip sooner; for heavy motor starts, a D-curve would ride through better. C-curve is the workhorse for mixed industrial panels. The 20 kA per IEC 60947-2 applies when the device is used as an industrial circuit breaker — that's the number for selectivity studies and SCCR compliance in machinery panels. The -40 °C low end is rare for an RCBO — most stop at -25 °C. That makes this unit suitable for unheated enclosures in cold climates or refrigeration plants. The 75 °C maximum is the storage/transport limit; the derated current at 70 °C (12.32 A) is the operating limit.","metaTitle":"Siemens 5SU1354-4KK16 SENTRON RCBO, 16 A C-curve, 10 kA, 2 M","metaDescription":"Siemens SENTRON RCBO 5SU1354-4KK16, 16 A C-curve, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 2-pole 1P+N, super resistant K design, -40 to 75 °C. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"36 mm","Height":"90 mm","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7da048cde48cab2d0dab4e2d7e816cc7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=215755&mlfb=5SU1354-4KK16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-4KK16/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-4KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-4KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}