{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-6KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-6KK06","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-6KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-6KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1354-6KK06 RCBO, 1P+N, 6 A rated at 30 °C, B tripping characteristic, 10 kA (EN 60898) / 35 kA (IEC 60947-2), 2 MW, halogen-free.","salesMarkdown":"The Siemens SENTRON 5SU1354-6KK06 is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) rated 6 A at 30 °C with a B tripping characteristic. It breaks fault currents up to 10 kA per EN 60898 and 35 kA per IEC 60947-2, covering the typical domestic and light commercial panel requirements. At 40 °C it derates to 5.7 A, at 50 °C to 5.4 A, and at 70 °C to 4.62 A — so in a warm enclosure the actual continuous current capacity drops. The 10 kA breaking capacity under EN 60898 is the domestic standard; the 35 kA under IEC 60947-2 gives headroom for industrial distribution where fault levels are higher. The rated insulation voltage is 264 V and the surge voltage resistance is 4 000 V, consistent with overvoltage category III and pollution degree 2 — typical for fixed-installation switchgear. ## Panel integration The 36 mm width (2 modular units) and 77 mm depth fit standard DIN-rail enclosures; installation depth is 70 mm.","metaTitle":"Siemens 5SU1354-6KK06 SENTRON RCBO, 6A B-Curve, 10kA EN 6089","metaDescription":"Siemens SENTRON 5SU1354-6KK06 RCBO, 1P+N, 6A rated at 30°C, B tripping curve, 10kA (EN 60898) / 35kA (IEC 60947-2). Halogen-free, 2 MW. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"274 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.7 A","at 45 °C rated value":"5.58 A","at 50 °C rated value":"5.4 A","at 55 °C rated value":"5.22 A","at 60 °C rated value":"5.1 A","at 65 °C rated value":"4.86 A","at 70 °C rated value":"4.62 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"10 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"35 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$74.41","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/58a5e9dc74c84e180d8fea53ca18dd40.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=142748&mlfb=5SU1354-6KK06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-6KK06/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1354-6KK06?","answer":"It is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of 5SU1354-6KK06?","answer":"10 kA per EN 60898 and 35 kA per IEC 60947-2."},{"question":"What is the rated current of 5SU1354-6KK06 and how does it derate with temperature?","answer":"Rated 6 A at 30 °C; derates to 5.7 A at 40 °C, 5.4 A at 50 °C, and 4.62 A at 70 °C."},{"question":"What compliance documentation does Siemens provide for 5SU1354-6KK06?","answer":"The device is halogen-free and silicon-free, and carries ratings per EN 60898 and IEC 60947-2. Specific RoHS/REACH/UL declarations should be confirmed at quote time from the supplier."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-6KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-6KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}