{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-7GV10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-7GV10","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-7GV10","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-7GV10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 10 A at 30 °C, Type C tripping characteristic, 10 kA (EN 60898) / 20 kA (IEC 60947-2), 230/240 V AC, 50 Hz, 2 MW, IP20.","salesMarkdown":"## Siemens 5SU1354-7GV10 — SENTRON RCBO, 10 A, Type C, 10 kA The Siemens 5SU1354-7GV10 is a SENTRON RCBO (residual current circuit breaker with overcurrent protection) in a 1P+N, 2-pole design, rated 10 A at 30 °C with a Type C tripping characteristic. Rated voltage is 230/240 V AC at 50 Hz, with an insulation voltage (Ui) of 264 V and surge voltage resistance of 4 kV. The 10 A rating at 30 °C derates linearly as ambient temperature rises: 9.5 A at 40 °C, 9.3 A at 45 °C, 9 A at 50 °C, 8.7 A at 55 °C, 8.5 A at 60 °C, 8.2 A at 65 °C, and 8 A at 70 °C. In a crowded panel where internal temperature hits 50 °C, the effective continuous current drops to 9 A — factor that into your load calculation rather than relying on the 30 °C nameplate figure. Dimensions are 77 mm depth, 36 mm width (2 MW), 90 mm height, with an installation depth of 70 mm. The 36 mm width matches standard DIN-rail modular devices — it occupies the same footprint as two single-pole MCBs side by side. The IP20 rating means the distribution board must be closed and conductors connected for the protection to be effective; this is normal for panelboard installation, not a standalone enclosure.","metaTitle":"Siemens 5SU1354-7GV10 SENTRON RCBO, 10 A, 10 kA, Type C","metaDescription":"Siemens 5SU1354-7GV10 SENTRON RCBO, 1P+N, 10 A rated at 30 °C, 10 kA per EN 60898, 20 kA per IEC 60947-2, Type C characteristic. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"278 g","at 30 °C rated value":"10 A","at 40 °C rated value":"9.5 A","at 45 °C rated value":"9.3 A","at 50 °C rated value":"9 A","at 55 °C rated value":"8.7 A","at 60 °C rated value":"8.5 A","at 65 °C rated value":"8.2 A","at 70 °C rated value":"8 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"10 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"20 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/82146a67e5322f8d41af76d417375278.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604370&mlfb=5SU1354-7GV10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-7GV10/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1354-7GV10 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a landed-cost figure."},{"question":"What is 5SU1354-7GV10's listed depth (77 mm) on this component line?","answer":"The depth is 77 mm, with an installation depth of 70 mm. Width is 36 mm (2 modular units), height is 90 mm."},{"question":"What compliance documentation does this brand provide for 5SU1354-7GV10 (RoHS, REACH, UL, IEC)?","answer":"The part is halogen-free and silicon-free, which supports RoHS and REACH compliance. It is rated per EN 60898 (10 kA) and IEC 60947-2 (20 kA). Specific UL or other jurisdictional certificates should be requested with your RFQ — the evidence does not list them directly."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-7GV10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-7GV10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}