{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1354-7RC32","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1354-7RC32","canonicalUrl":"https://aoctrl.com/siemens/5SU1354-7RC32","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1354-7RC32","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 32 A, 2-pole, 2-module, C characteristic, Type A, 30 mA, 10 kA (EN 60898) / 15 kA (IEC 60947-2).","salesMarkdown":"Type A residual-current detection covers pulsating DC fault currents and sinusoidal AC — the common choice for circuits with single-phase rectifiers, switching power supplies, or electronic loads that generate smooth DC ripple. The higher IEC figure applies when the device is used as a circuit breaker in industrial distribution; the EN figure governs residential or commercial final circuits. Either way, the 15 kA rating gives headroom for coordination with an upstream 25 kA or 36 kA main breaker in a typical panel. Snap-on DIN-rail mount, 36 mm wide (2 MW), 70 mm deep. Mounting position any, so it fits horizontal or vertical busbars without derating.","metaTitle":"Siemens 5SU1354-7RC32 SENTRON RCBO, 32 A, 30 mA, Type A, C-C","metaDescription":"Siemens SENTRON 5SU1354-7RC32 RCBO, 32 A rated, 30 mA residual, Type A, C characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2). Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","at AC / rated value":"32 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Residual Current Type":"A","Energy Limitation Class":"3","according to EN 61346-2":"F","according to IEC 81346-2":"F","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","according to EN 60898 / rated value":"10 kA","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 V","according to IEC 60947-2 / rated value":"15 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage / Of The Operating Voltage":"AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=371900&mlfb=5SU1354-7RC32","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1354-7RC32/alternatives.json"},"ai":{"faq":[{"question":"Will 5SU1354-7RC32 drop into a panel specified around 5SL4106-7CC without rewiring?","answer":"No. The 5SL4106-7CC is a 1-pole 18 mm MCB; the 5SU1354-7RC32 is a 2-pole 36 mm RCBO. The footprint is double the width, and the wiring differs because the RCBO requires a neutral connection for the residual-current circuit. Panel layout and busbar arrangement must be modified."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1354-7RC32","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1354-7RC32 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}