{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1356-1GV16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1356-1GV16","canonicalUrl":"https://aoctrl.com/siemens/5SU1356-1GV16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1356-1GV16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole, 16 A, 30 mA, Type AC, tripping characteristic C, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, IP20, halogen-free, -40 to 75 °C.","salesMarkdown":"The Siemens 5SU1356-1GV16 is a SENTRON RCBO (residual current circuit breaker with overcurrent protection) combining a 16 A rated current with a 30 mA residual-current trip in a single 2-module-wide (36 mm) package. Full 16 A rating holds at 30 °C ambient; at 40 °C it derates to 15.2 A, at 50 °C to 14.4 A, and at 70 °C to 12.32 A. Mounting position is unrestricted, and the supply can enter from either top or bottom — no forced orientation in the panel. IP20 applies once the distribution board is installed and conductors are connected — the front face is touch-protected.","metaTitle":"Siemens 5SU1356-1GV16 SENTRON RCBO, 16 A, 30 mA, Type AC, 6","metaDescription":"Siemens 5SU1356-1GV16 SENTRON RCBO, 2-pole, 16 A rated, 30 mA residual current, Type AC, 6 kA breaking capacity per EN 60898. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"16 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"275 g","at 30 °C / rated value":"16 A","at 40 °C / rated value":"15.2 A","at 45 °C / rated value":"14.88 A","at 50 °C / rated value":"14.4 A","at 55 °C / rated value":"13.92 A","at 60 °C / rated value":"13.6 A","at 65 °C / rated value":"12.96 A","at 70 °C / rated value":"12.32 A","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"15 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/42e5d3f20d7ecc775d7d3e0535922239.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604372&mlfb=5SU1356-1GV16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1356-1GV16/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SU1356-1GV16?","answer":"6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure applies when the RCBO is applied under the IEC 60947-2 standard for industrial use."},{"question":"What temperature derating applies to 5SU1356-1GV16?","answer":"Full 16 A at 30 °C; derates to 15.2 A at 40 °C, 14.4 A at 50 °C, and 12.32 A at 70 °C. Ambient temperature inside the enclosure governs the actual continuous rating."},{"question":"Where can I buy 5SU1356-1GV16?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1356-1GV16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1356-1GV16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}