{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1356-6GV10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1356-6GV10","canonicalUrl":"https://aoctrl.com/siemens/5SU1356-6GV10","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1356-6GV10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1356-6GV10, RCBO, 2-pole, 10 A rated, B-curve, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 modular width units.","salesMarkdown":"It's rated 10 A at 30 °C with a 6 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2, so it handles both overcurrent and earth-fault protection in one DIN-rail footprint — no separate RCD needed downstream. ## Ratings that matter for panel fit Type A residual current detection catches pulsating DC fault currents from electronics and single-phase rectifiers, which a plain AC type would miss. At 40 °C ambient the continuous rating derates to 9.5 A; at 50 °C it's 9 A. If the panel runs hot — say above 55 °C — plan for 8.7 A or less. The 77 mm depth and 36 mm width (2 MW) mean it fits standard 18 mm/module DIN-rail enclosures; supply can land top or bottom.","metaTitle":"Siemens 5SU1356-6GV10 SENTRON RCBO, 2P, 10 A, B-Curve, Type","metaDescription":"Siemens 5SU1356-6GV10 SENTRON RCBO, 2-pole, 10 A rated, B-curve, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2). Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"10 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"275 g","at 30 °C / rated value":"10 A","at 40 °C / rated value":"9.5 A","at 45 °C / rated value":"9.3 A","at 50 °C / rated value":"9 A","at 55 °C / rated value":"8.7 A","at 60 °C / rated value":"8.5 A","at 65 °C / rated value":"8.2 A","at 70 °C / rated value":"8 A","Number Of Modular Width Units":"2","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"15 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"264 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fb72619c2ed75b31fd11865e749fe377.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604373&mlfb=5SU1356-6GV10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1356-6GV10/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SU1356-6GV10?","answer":"6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure applies when the installation standard allows the IEC 60947-2 rating."},{"question":"Will 5SU1356-6GV10 drop into a panel specified around 5SY5202-6 without rewiring?","answer":"The 5SU1356-6GV10 is an RCBO (combined RCD+MCB), while 5SY5202-6 is a standalone MCB. They serve different protection functions — the RCBO adds residual current detection that the MCB alone doesn't provide. Physical dimensions differ; verify DIN-rail space and wiring topology before substituting."},{"question":"Where can I buy 5SU1356-6GV10?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1356-6GV10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1356-6GV10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}