{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1356-7GV10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1356-7GV10","canonicalUrl":"https://aoctrl.com/siemens/5SU1356-7GV10","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7GV10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 10 A, C-characteristic, 30 mA type A, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 2 MW, bulk packaging.","salesMarkdown":"It protects a single-phase final subcircuit against both overload/short-circuit and earth leakage, with a 10 A rated current, C-trip curve, and 30 mA type A residual sensitivity. Snaps onto DIN rail (EN 60715) in any mounting position, occupying 2 MW at 36 mm wide. Rated IP20 with conductors connected and the distribution board installed, so it's intended for enclosed use only. The 30 mA type A residual detects pulsating DC fault currents as well as sinusoidal AC, covering modern electronics and variable-speed drives downstream. Energy limitation class 3 keeps let-through energy low, protecting downstream wiring and connected equipment during a fault. The nearest functional peer is the 5SU9354-7KK16, which shares the same 1P+N pole configuration, C-curve, 30 mA type A sensitivity, and identical 77×36×90 mm footprint. The key difference: the 5SU9354-7KK16 carries a higher 10 kA breaking capacity under both EN 60898 and IEC 60947-2, versus the 5SU1356-7GV10's 6 kA / 15 kA split. If your panel's prospective fault current exceeds 6 kA at the point of installation, the 5SU9354-7KK16 is the safer drop-in. For standard domestic or light commercial distribution boards where 6 kA is adequate, the 5SU1356-7GV10 is the economical fit.","metaTitle":"Siemens 5SU1356-7GV10 SENTRON RCBO, 10A C-Char, 30mA, 6kA","metaDescription":"Siemens 5SU1356-7GV10 SENTRON RCBO, 1P+N, 10A, C-curve, 30mA residual current, 6kA (EN 60898) / 15kA (IEC 60947-2). Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"274 g","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"15 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4cb139fc3b845a1c95b90ee98eebcf19.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604375&mlfb=5SU1356-7GV10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7GV10/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 5SU1356-7GV10?","answer":"The 5SU9354-7KK16 is the closest functional peer — same pole config, same C-curve, same 30 mA type A sensitivity, same physical footprint. The main difference is a higher 10 kA breaking capacity on the peer versus the 6 kA / 15 kA dual rating on this part."},{"question":"Where can I buy 5SU1356-7GV10 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume and delivery window."},{"question":"What are the key ratings of 5SU1356-7GV10?","answer":"10 A rated current, C-trip characteristic, 30 mA type A residual current, 6 kA per EN 60898 and 15 kA per IEC 60947-2, 230/240 V AC, 50 Hz, 1P+N in a 2 MW (36 mm) wide package."},{"question":"Will 5SU1356-7GV10 drop into a panel specified around 5SU9354-7KK16?","answer":"Yes — both share the same 77×36×90 mm dimensions, same DIN-rail mounting, same 2 MW width, same top/bottom supply entry, and same pole configuration. Physical fit is identical; the only difference is the breaking capacity rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1356-7GV10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1356-7GV10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}