{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1356-7GV16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1356-7GV16","canonicalUrl":"https://aoctrl.com/siemens/5SU1356-7GV16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7GV16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole 1P+N, 16 A rated, C tripping characteristic, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 36 mm wide, current lifecycle.","salesMarkdown":"The Siemens 5SU1356-7GV16 is a SENTRON RCBO combining overcurrent and residual current protection in a 2-module (36 mm) wide package. The C-curve trips magnetically at 5–10× In, so a 16 A unit holds through a motor start surge that a B-curve would catch. Type A residual detects pulsating DC superimposed on AC — covers variable-speed drives, LED drivers, and UPS-fed circuits where pure AC-sensitive (Type AC) devices may blind. The 1P+N pole configuration switches the line conductor only; the neutral is switched internally for isolation but not protected against overcurrent. Derating is published: at 40 °C ambient the continuous rating drops to 15.2 A, at 50 °C to 14.4 A, and at 70 °C to 12.32 A — factor this into the load calculation if the panel runs hot. IP20 applies only when the distribution board is installed with connected conductors; the device itself is not rated for exposed or washdown environments. The 5SU1356-7GV16 carries a current lifecycle status.","metaTitle":"Siemens 5SU1356-7GV16 SENTRON RCBO, 2-pole 16 A C-curve Type","metaDescription":"Siemens 5SU1356-7GV16 SENTRON RCBO, 2-pole 1P+N, 16 A, C characteristic, Type A residual current, 6 kA (EN 60898) / 15 kA (IEC 60947-2). Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"16 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"274 g","at 30 °C / rated value":"16 A","at 40 °C / rated value":"15.2 A","at 45 °C / rated value":"14.88 A","at 50 °C / rated value":"14.4 A","at 55 °C / rated value":"13.92 A","at 60 °C / rated value":"13.6 A","at 65 °C / rated value":"12.96 A","at 70 °C / rated value":"12.32 A","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"15 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc0ae4b2e457d8d9441b8b00ace4d95c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=604376&mlfb=5SU1356-7GV16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7GV16/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU1356-7GV16 and how do I get a price?","answer":"The 5SU1356-7GV16 is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"What is the difference between 5SU1356-7GV16 and 5SL6550-7BB?","answer":"The 5SL6550-7BB is a different class — a miniature circuit breaker (MCB) without residual current protection. The 5SU1356-7GV16 is an RCBO that combines overcurrent and Type A residual current protection in one unit. They are not drop-in replacements; the RCBO occupies 2 MW (36 mm) versus the MCB's 1 MW, and the wiring differs because the neutral is switched on the RCBO."},{"question":"What compliance documentation does 5SU1356-7GV16 carry?","answer":"The device is halogen-free and silicon-free. It is designed to EN 60898 (6 kA) and IEC 60947-2 (15 kA), with overvoltage category III and pollution degree 2. Specific RoHS/REACH/UL documentation should be confirmed at time of order against the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1356-7GV16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1356-7GV16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}