{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1356-7KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1356-7KK06","canonicalUrl":"https://aoctrl.com/siemens/5SU1356-7KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 6 A at 30 °C, C-trip characteristic, 6 kA / 25 kA dual breaking capacity, 2 MW, depth 77 mm.","salesMarkdown":"## Ratings that matter The 36 mm width (2 modular units) fits standard DIN-rail enclosures, and the depth of 77 mm (70 mm inside the board) leaves clearance for wiring troughs. The IP20 rating applies once the board is closed and cables are installed.","metaTitle":"Siemens 5SU1356-7KK06 SENTRON RCBO, 6A C-curve, 6/25kA","metaDescription":"Siemens SENTRON RCBO 1P+N, 6 A rated at 30 °C, C characteristic, 6 kA (EN 60898) and 25 kA (IEC 60947-2). Current production, halogen-free. Sourced to order. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"269 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.7 A","at 45 °C rated value":"5.58 A","at 50 °C rated value":"5.4 A","at 55 °C rated value":"5.22 A","at 60 °C rated value":"5.1 A","at 65 °C rated value":"4.86 A","at 70 °C rated value":"4.62 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"25 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$39.37","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4de3772b371821dca6e0a6d31c5fe870.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=142312&mlfb=5SU1356-7KK06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1356-7KK06/alternatives.json"},"ai":{"faq":[{"question":"What are the physical dimensions of the 5SU1356-7KK06?","answer":"Width is 36 mm (2 modular units), depth 77 mm (70 mm installation depth), height 90 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1356-7KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1356-7KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}