{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1454-1KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1454-1KK06","canonicalUrl":"https://aoctrl.com/siemens/5SU1454-1KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1454-1KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU1454-1KK06 RCBO, 2-pole (1P+N), 6 A rated, C trip curve, 100 mA residual current, 10 kA breaking capacity, 50 Hz, IP20.","salesMarkdown":"The Siemens SENTRON 5SU1454-1KK06 is a 2-pole (1P+N) residual-current circuit breaker with overcurrent protection — an RCBO — combining a 6 A thermal-magnetic MCB (C curve) and a 100 mA AC-type RCD in one 36 mm wide, 2-module-width housing. It protects a single-phase final subcircuit against overload, short-circuit (10 kA Icn per EN 60898, 35 kA Icu per IEC 60947-2), and earth faults up to the rated residual current. The neutral pole is switched, so the outgoing neutral is disconnected when the device trips or is manually opened. Its 36 mm width (2 module units) matches the standard SENTRON modular grid. Supply can enter from either top or bottom, which simplifies wiring when the busbar arrangement dictates the feed direction. The IP20 rating applies once installed with conductors connected — the panel enclosure provides the environmental seal. The C-curve trip characteristic means the magnetic release operates at 5 to 10 times rated current (30–60 A for this 6 A unit), suited for circuits with moderate inrush — lighting banks, small motor loads, control transformers. The 100 mA residual-current sensitivity (AC type) detects sinusoidal earth faults only; it is not suitable for pulsating DC or smooth DC fault currents (those need type A or F). The 10 kA Icn rating covers the majority of domestic and light commercial service-entrance fault levels; the 35 kA Icu rating gives additional headroom for industrial panels with higher prospective short-circuit current — the device can interrupt a 35 kA fault once (Icu) and still be functional afterward, whereas Icn is the rated short-circuit capacity for the full duty cycle.","metaTitle":"Siemens SENTRON 5SU1454-1KK06 RCBO, 6 A, C curve, 100 mA, 10","metaDescription":"Siemens SENTRON 5SU1454-1KK06 RCBO, 2-pole 1P+N, 6 A rated, C trip characteristic, 100 mA residual current, 10 kA Icn. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230/240 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"284 g","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"10 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"35 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"100 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","operational current / at AC / rated value":"6 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c98ef4398e7b9d0975228f12331eb8e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=203424&mlfb=5SU1454-1KK06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1454-1KK06/alternatives.json"},"ai":{"faq":[{"question":"What is the rated current and residual current of 5SU1454-1KK06?","answer":"The rated operational current is 6 A at 230/240 V AC, and the rated residual tripping current is 100 mA (AC type)."},{"question":"What is the breaking capacity of 5SU1454-1KK06?","answer":"The Icn (rated short-circuit capacity per EN 60898) is 10 kA; the Icu (ultimate breaking capacity per IEC 60947-2) is 35 kA."},{"question":"Where can I buy 5SU1454-1KK06?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the physical size of 5SU1454-1KK06?","answer":"Width is 36 mm (2 module units), height is 90 mm, depth is 77 mm, and installation depth is 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1454-1KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1454-1KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}