{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1653-7KK10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1653-7KK10","canonicalUrl":"https://aoctrl.com/siemens/5SU1653-7KK10","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1653-7KK10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole (1P+N), 10 A rated current, 300 mA residual current, Type A, tripping characteristic C, 4.5 kA / 15 kA breaking capacity, 2 MW, halogen-free, silicon-free.","salesMarkdown":"The Siemens 5SU1653-7KK10 is a SENTRON RCBO (residual current circuit breaker with overcurrent protection) in a 2-module-width (36 mm) housing, combining a 10 A MCB with a 300 mA Type A RCD in one unit. It's designed for 230/240 V AC, 50 Hz single-phase circuits where you need both overcurrent and earth-fault protection in a single DIN-rail device — common in distribution boards for commercial or light industrial final circuits. The 10 A rated current and C tripping characteristic handle moderate inrush loads. The 300 mA Type A residual current detects sinusoidal AC and pulsed DC faults. Breaking capacity is rated at 4.5 kA per EN 60898 and 15 kA per IEC 60947-2. The EN 60898 figure governs installation in a domestic or commercial distribution board where the prospective short-circuit current (PSCC) is under 4.5 kA. The 15 kA IEC rating applies when the RCBO is used in an industrial context per IEC 60947-2 — for example, in a panel with a transformer feeding a higher fault-current bus. That dual rating gives you flexibility: it's certified for both standards, so you can specify it into either type of assembly without a separate industrial-grade device. At 2 MW (36 mm wide, 2 module widths), it occupies two adjacent slots in a distribution board or sub-panel. Halogen-free and silicon-free construction matters in environments where outgassing during a fault could contaminate sensitive equipment or where silicone vapors interfere with paint or bonding processes.","metaTitle":"Siemens 5SU1653-7KK10 SENTRON RCBO, 10A, 300mA, Type A, 2-Po","metaDescription":"Siemens 5SU1653-7KK10 SENTRON RCBO, 10A rated current, 300mA residual current, Type A, 2-pole (1P+N), 4.5kA (EN 60898) / 15kA (IEC 60947-2) breaking capacity. Active production, so","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230/240 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"267 g","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"100 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"15 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","operational current / at AC / rated value":"10 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b098b74e1c66adda63f85b6f99ff33f8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=351186&mlfb=5SU1653-7KK10","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1653-7KK10/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1653-7KK10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1653-7KK10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}