{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU1656-1KV40","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU1656-1KV40","canonicalUrl":"https://aoctrl.com/siemens/5SU1656-1KV40","factsUrl":"https://aoctrl.com/api/mcp/products/5SU1656-1KV40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 5SU1656-1KV40 FI/LS-PROTECTOR, Type AC (WS), D=70mm, IΔn 300mA, 6kA, 1+N-pole, C 40A.","salesMarkdown":"## What this RCBO does in the panel The Siemens 5SU1656-1KV40 is a combined residual-current and overcurrent protective device (RCBO) — what Siemens calls an FI/LS protector. It packs a Type AC residual-current unit rated at 300 mA trip threshold and a C-curve 40 A miniature circuit breaker into a single 1+N-pole module, 70 mm wide on the DIN rail. The 40 A thermal element carries continuous loads up to that current. The 300 mA residual threshold is a deliberate choice: it is higher than the 30 mA required for personal shock protection, so it is typically specified for circuits where the natural leakage from filters, VFDs, or long cable runs would cause unwanted trips on a 30 mA device. This makes it a fit for distribution sub-mains, lighting circuits with electronic ballasts, or equipment circuits where the earth leakage budget is tight. Pulsating DC residuals (from rectifiers, half-wave devices, or VFDs) will not reliably trip this device — that is the limitation of Type AC. If the downstream load includes any power electronics, a Type A or Type F RCD would be the correct choice.","metaTitle":"Siemens 5SU1656-1KV40 RCBO, Type AC 300mA, 6kA, 1+N C 40A","metaDescription":"Siemens 5SU1656-1KV40 FI/LS protector, Type AC, 300mA residual, 6kA breaking capacity, 1+N-pole C-curve 40A. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=64395&mlfb=5SU1656-1KV40","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU1656-1KV40/alternatives.json"},"ai":{"faq":[{"question":"What is the 5SU1656-1KV40 used for?","answer":"It is a combined residual-current and overcurrent protector (RCBO) for 1+N circuits, rated 40 A C-curve with 300 mA Type AC residual detection and 6 kA breaking capacity. It protects against both overload/short-circuit and sinusoidal earth faults in a single DIN-rail module."},{"question":"Where can I buy the 5SU1656-1KV40?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What does Type AC mean on this RCBO?","answer":"Type AC means it detects sinusoidal AC residual currents only. It will not reliably trip on pulsating DC residuals from rectifiers, VFDs, or half-wave devices — for those loads, a Type A or Type F RCD is required."},{"question":"What is the difference between a 30 mA and 300 mA RCD?","answer":"30 mA is the threshold for personal shock protection. 300 mA is for fire protection and equipment protection on circuits with naturally higher earth leakage — it avoids nuisance tripping on VFDs, filters, or long cable runs where the leakage budget is tight."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU1656-1KV40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU1656-1KV40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}