{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9304-7KX16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9304-7KX16","canonicalUrl":"https://aoctrl.com/siemens/5SU9304-7KX16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9304-7KX16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU9304-7KX16, RCBO, 2-pole, 16 A rated, 30 mA Type A residual current, C-curve, 10 kA breaking capacity per EN 60898, 1 MW DIN-rail width.","salesMarkdown":"The Siemens 5SU9304-7KX16 is a 2-pole RCBO from the SENTRON series — an RCD-operated circuit breaker combining overcurrent and residual current protection in one 18 mm-wide module. It's rated 16 A at 30 °C with a 30 mA Type A residual trip, C-curve magnetic release, and 10 kA breaking capacity per EN 60898 (also rated 10 kA per IEC 60947-2). That 30 mA Type A trip catches pulsating DC fault currents from electronics and single-phase rectifiers — common in modern loads like switched-mode supplies and LED drivers. The C-curve (5-10x In) handles motor inrush and capacitive loads without nuisance trips, while the 10 kA SCCR at 230/400 V means it clears a hard fault without upstream breaker coordination issues in a residential or light commercial panel. Snaps onto standard DIN rail, one modular width (18 mm). Depth is 77 mm, installation depth 70 mm — fits flush in a 125 mm-tall enclosure with the gland plate clear. Mounting position any, so it works in vertical or horizontal busbar configurations. Supply feeds from below per the position-of-power-supply-cord spec. Derating matters here: at 30 °C it carries the full 16 A; at 40 °C it's 15.2 A; at 45 °C it drops to 14.56 A; at 50 °C it's 14.08 A; at 55 °C it's 13.76 A. Touch protection is built in. Energy limitation class 3 — fast arc quenching limits let-through energy, which helps with downstream coordination on a 10 kA fault.","metaTitle":"Siemens 5SU9304-7KX16 SENTRON RCBO, 2-pole, 16 A, 30 mA, C-c","metaDescription":"Siemens 5SU9304-7KX16 SENTRON RCBO: 2-pole, 16 A, 30 mA Type A, C-curve, 10 kA (EN 60898). Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"18 mm","Height":"125 mm","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/afd84d4cd92063d3fe7003ce39deab53.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=558612&mlfb=5SU9304-7KX16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU9304-7KX16/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9304-7KX16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9304-7KX16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}