{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9336-7CN06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9336-7CN06","canonicalUrl":"https://aoctrl.com/siemens/5SU9336-7CN06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9336-7CN06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU9336-7CN06 RCBO, 1P+N, Type A, 30 mA, C-Characteristic, In: 6 A, Un AC: 230 V, Icn: 6 kA per EN 60898 / 10 kA per IEC 60947-2.","salesMarkdown":"It combines overcurrent protection (C-curve, 6 A rated at 30 °C) with residual current detection (30 mA, Type A) in a single 2-module-wide unit. That means one device handles both thermal-magnetic trip for overloads and short-circuits, and ground-fault interruption for sinusoidal AC and pulsating DC residual currents. C-curve characteristic means the magnetic trip fires at 5 to 10 times In (30–60 A for this 6 A unit), suited for mixed resistive and moderate inductive loads like lighting circuits, small motors, and control transformers. The 30 mA residual sensitivity is the standard for personal protection against fatal shock in most IEC-based codes. Type A detection covers both pure AC fault currents and pulsating DC — the kind you get from single-phase rectifiers in electronics or LED drivers. The 4 kV rated surge voltage (impulse withstand) means it survives switching transients and nearby lightning-induced spikes without nuisance tripping or damage. Snaps onto DIN rail, 2 module widths. Mounting position is unrestricted. Supply can feed from top or bottom. Depth is 77 mm with 70 mm installation depth. Halogen-free and silicon-free.","metaTitle":"Siemens 5SU9336-7CN06 SENTRON RCBO, 6 A, C-Char, 30 mA, Type","metaDescription":"Siemens SENTRON 5SU9336-7CN06 RCBO, 6 A, C-curve, 30 mA Type A, 6 kA (EN 60898) / 10 kA (IEC 60947-2). Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"108 mm","title":"5SU9336-7CN06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO, Icn: 6 kA, 1P+N, Type A, 30 mA, C-Char, In: 6 A, Un AC: 230V","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"3P","Number Of Poles":"3","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"400 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"650 g","at 30 °C rated value":"6 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"125 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"3","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"440 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"0.75 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2029266c4024176168634ea103009a16.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1440173&mlfb=5SU9336-7CN06"},"ai":{"faq":[{"question":"What does Type A residual current detection mean?","answer":"Type A detects both sinusoidal AC fault currents and pulsating DC — the kind produced by single-phase rectifiers in electronics, LED drivers, and switched-mode power supplies. Standard AC-only RCDs may not trip on pulsating DC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9336-7CN06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9336-7CN06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}