{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9356-7KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9356-7KK06","canonicalUrl":"https://aoctrl.com/siemens/5SU9356-7KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SU9356-7KK06, 1P+N, C-curve, 6 A, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 MW, 230/240 V AC, IP20.","salesMarkdown":"The Siemens 5SU9356-7KK06 is a SENTRON RCBO — an RCD-operated circuit breaker combining overcurrent and residual-current protection in a single 2-module-wide (36 mm) package. That dual rating is the key spec for panel builders: the 10 kA figure under 60947-2 gives you SCCR headroom for industrial panels where fault currents can run higher than a residential 6 kA installation. The 4 000 V surge voltage resistance and overvoltage category III mean it's rated for fixed-installation distribution boards, not just final circuits. At 40 °C it derates to 5.64 A, at 50 °C to 5.22 A, and at 55 °C to 4.86 A. Depth is 77 mm, installation depth 70 mm, and it's IP20 once installed in a distribution board with conductors connected. That's standard for enclosed panel gear; no washdown rating here. Degree of pollution 2 and overvoltage category III round out the installation class. No UL or CSA listing is stated in the spec record, so verify with your local code authority if you're specifying for a North American panel.","metaTitle":"Siemens 5SU9356-7KK06 SENTRON RCBO, 1P+N, C-curve, 6 A, 6/10","metaDescription":"Siemens SENTRON 5SU9356-7KK06 RCBO, 1P+N, C-curve 6 A, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 MW, active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"36 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230/240 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCD-operated circuit breaker","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"280 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.64 A","at 45 °C rated value":"5.46 A","at 50 °C rated value":"5.22 A","at 55 °C rated value":"4.86 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"264 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"0.75 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79f6610cfebb3bc98ed563eb1e55c601.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629376&mlfb=5SU9356-7KK06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KK06/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SU9356-7KK06 and how do I get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"Will 5SU9356-7KK06 drop into a panel that was specified around 5SU9354-7KK16 without rewiring?","answer":"Yes — both are 1P+N, 2 MW (36 mm) SENTRON RCBOs. The 5SU9356-7KK06 is a 6 A C-curve; the 5SU9354-7KK16 is a 16 A C-curve. Same footprint, same pole configuration, same busbar compatibility. No rewiring needed; just verify the load current matches the 6 A rating."},{"question":"What compliance documentation does this brand provide for 5SU9356-7KK06?","answer":"The part is designed to EN 60898 and IEC 60947-2, halogen-free and silicon-free. It carries CE marking for European markets. No UL or CSA listing is stated in the spec record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9356-7KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9356-7KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}