{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9356-7KP06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9356-7KP06","canonicalUrl":"https://aoctrl.com/siemens/5SU9356-7KP06","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KP06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 6 A rated, Type C tripping characteristic, 30 mA Type A residual current, 1P+N, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 36 mm wide.","salesMarkdown":"## RCD-operated circuit breaker, 6 A Type C, 30 mA Type A The Siemens 5SU9356-7KP06 is a SENTRON RCBO combining overcurrent protection and residual current detection in a single 36 mm wide module. Rated 6 A with a Type C tripping characteristic, it handles inrush from motor starters and lighting ballasts without nuisance trips. The Type A residual current element detects pulsating DC fault currents up to 30 mA, covering electronics and variable-speed drives. Breaking capacity is 6 kA per EN 60898 and 10 kA per IEC 60947-2, so it clears line-to-neutral faults on a standard 230/400 V distribution board without upstream reinforcement. ## Mounting and conductor range Two width units (36 mm) snap onto a DIN rail. Installation depth is 70 mm; the overall depth including terminals is 77 mm — check gland-plate clearance if the enclosure is shallow. Rated 6 A at 30 °C ambient. Derate to 5.64 A at 40 °C, 5.46 A at 45 °C, 5.22 A at 50 °C, and 4.86 A at 55 °C.","metaTitle":"Siemens 5SU9356-7KP06 SENTRON RCBO, 6A Type C, 30mA Type A,","metaDescription":"Siemens 5SU9356-7KP06 SENTRON RCBO, 6 A rated, Type C trip, 30 mA Type A residual current, 1P+N, 6 kA (EN 60898) / 10 kA (IEC 60947-2). Current lifecycle. Sourced to order. Request","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Solid":"0.75 ... 35 mm²","Width":"36 mm","Height":"90 mm","Maximum":"1.5 W","Stranded":"0.75 ... 35 mm²","at 30 Cel":"6 A","at 40 Cel":"5.64 A","at 45 Cel":"5.46 A","at 50 Cel":"5.22 A","at 55 Cel":"4.86 A","Halogen-Free":"Yes","Silicon-Free":"Yes","During Storage":"-40 ... +75 °C","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +45 °C","Product designation":"RCD-operated circuit breaker","Protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage category":"III","Design of the product":"Instantaneous","Energy limiting class":"3","Number of width units":"2","Type of fault current":"A","Number of poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","circuit-breaker / Design":"5SU9","Current / at AC / rated value":"6 A","Tripping characteristic class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / of power supply cord":"Either top or bottom","Number of poles / with protection":"1","acc. to IEC 60947-2 / rated value":"10 kA","Product feature / Touch protection":"Yes","Supply voltage frequency / rated value":"50 Hz","Tripping residual current / rated value":"30 mA","Influence of the surrounding temperature":"Max. 95% humidity","Surge current resistance / at (8/20) μs":"1 kA","Tightening torque / with screw-type terminals":"2.5 ... 3 N·m","Product function / neutral conductor switching":"Yes","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79f6610cfebb3bc98ed563eb1e55c601.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629400&mlfb=5SU9356-7KP06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KP06/alternatives.json"},"ai":{"faq":[{"question":"What conductor sizes does the 5SU9356-7KP06 accept?","answer":"Solid or stranded copper from 0.75 to 35 mm²."},{"question":"What is the depth of the 5SU9356-7KP06?","answer":"Overall depth is 77 mm; installation depth is 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9356-7KP06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9356-7KP06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}