{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9356-7KP16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9356-7KP16","canonicalUrl":"https://aoctrl.com/siemens/5SU9356-7KP16","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KP16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU9 RCBO, 16 A, Type A, 30 mA, 6 kA per EN 60898 / 10 kA per IEC 60947-2, 1P+N, 2-module (36 mm), tripping characteristic C.","salesMarkdown":"The Siemens 5SU9356-7KP16 is a SENTRON 5SU9-series RCBO — an RCD-operated circuit breaker combining overcurrent and residual-current protection in a single 36 mm-wide, 2-module housing. It's rated 16 A with a Type C tripping characteristic and Type A fault-current sensitivity, making it a go-to choice for final circuits in commercial and residential distribution boards where both short-circuit and earth-fault protection are needed on a single DIN-rail footprint. The 16 A rating at 30 °C is the headline number, but the derating curve tells the real story for a warm enclosure: at 40 °C it's 15.04 A, at 45 °C it's 14.56 A, and at 55 °C it drops to 12.96 A. The EN figure governs domestic and light commercial boards; the IEC figure applies when the device is specified per the industrial standard. Either way, it's rated for the fault levels typical of a sub-distribution board fed from a transformer of up to about 630 kVA. The energy limiting class of 3 means it lets through less let-through energy (I²t) than class 1 or 2 devices — helpful for downstream cable protection. Type A residual-current detection covers sinusoidal AC faults plus pulsating DC faults up to 6 mA smooth DC — the standard for circuits with electronics, rectifiers, or single-phase drives. The instantaneous design (no intentional delay) trips within 40 ms at rated residual current, which is the norm for socket-outlet circuits where personnel protection is the goal. Supply can enter from either top or bottom — no mandatory orientation. The terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm², which covers everything from 1.5 mm² lighting circuits to 10 mm² submains. Touch protection is built in (fingertip-safe terminals per the standard). Mounting position is any — horizontal, vertical, flat — no derating required for orientation.","metaTitle":"Siemens 5SU9356-7KP16 SENTRON RCBO, 16A Type A, 6kA/10kA","metaDescription":"Siemens 5SU9356-7KP16 SENTRON RCBO, 16A rated, Type A, 30mA, 6kA EN/10kA IEC, 1P+N, 2-module. Active production, available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"36 mm","Height":"90 mm","Product Status":"Active","Temp Operating Max":"45 °C","Temp Operating Min":"-25 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79f6610cfebb3bc98ed563eb1e55c601.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629402&mlfb=5SU9356-7KP16","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU9356-7KP16/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9356-7KP16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9356-7KP16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}