{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SU9406-0KK25","brand":"Siemens","brandSlug":"siemens","productSlug":"5SU9406-0KK25","canonicalUrl":"https://aoctrl.com/siemens/5SU9406-0KK25","factsUrl":"https://aoctrl.com/api/mcp/products/5SU9406-0KK25","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SU9406-0KK25 RCBO, RCD-operated circuit breaker, 1P+N, 25 A, 6 kA, Type B, 230/240 V AC, 1 MW unit, 18 mm wide.","salesMarkdown":"The Siemens SENTRON 5SU9406-0KK25 is a 1P+N RCD-operated circuit breaker — an RCBO — combining overcurrent and residual-current protection in a single 18 mm wide modular unit. Rated 25 A at 30 °C with a B tripping characteristic, it interrupts fault currents up to 6 kA per EN 60898 and IEC 60947-2. The 1P+N design switches the phase and monitors the neutral, protecting one live conductor while the neutral is switched but not protected. This makes it a direct fit for single-phase final circuits in DIN-rail distribution boards where space is tight — one module width per pole saves rail length. ## Ratings that govern the real application The 25 A rating at 30 °C is the headline number, but the derating curve matters more in a warm panel: at 40 °C it's 23.5 A, at 45 °C it's 22.75 A, at 50 °C it's 21.75 A, and at 55 °C it's 20.25 A. If your enclosure ambient runs above 40 °C, size the circuit for the derated current — not the 25 A sticker. The B curve (3–5 In instantaneous trip) suits resistive and general-purpose loads — lighting, small appliances, control transformers — where inrush is low. For motor or capacitor loads, a C or D curve would be the better call. One modular width (18 mm) per unit, 77 mm depth, 125 mm height. Installation depth is 70 mm — factor that into enclosure depth, especially with wiring ducts.","metaTitle":"Siemens 5SU9406-0KK25 SENTRON RCBO, 25A, 6kA, Type B, 1P+N","metaDescription":"Siemens SENTRON 5SU9406-0KK25 RCBO, 25 A rated, 6 kA breaking capacity, 1P+N, Type B, 230/240 V AC, 1 MW unit. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"18 mm","Height":"125 mm","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1c76d74a4e278fc08fd38d1f8d77a7dc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=629422&mlfb=5SU9406-0KK25","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SU9406-0KK25/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SU9406-0KK25","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SU9406-0KK25 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}