{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1313-1GV16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1313-1GV16","canonicalUrl":"https://aoctrl.com/siemens/5SV1313-1GV16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1313-1GV16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole, 16 A, Type C, 4.5 kA per EN 60898, 1 MW unit width, IP20, halogen-free.","salesMarkdown":"The Siemens SENTRON 5SV1313-1GV16 is a 2-pole RCBO (residual current circuit breaker with overcurrent protection) rated 16 A at 30 °C with a Type C tripping characteristic and AC residual current sensing. It occupies a single 18 mm modular width unit on a DIN rail — the standard 1 MW footprint — so it fits a panel already laid out for miniature breakers or RCCBs without re-spacing the rail. Breaking capacity is 4.5 kA per EN 60898 and 5 kA per IEC 60947-2, which covers most commercial and light industrial distribution boards supplied from a transformer of typical impedance. The 5 kA IEC rating gives a bit more headroom for coordination studies where the prospective fault current lands between the two standards. ## Thermal derating and mounting The 16 A rating holds at 30 °C ambient. At 40 °C it derates to 15.2 A, at 50 °C to 14.24 A, and at 70 °C to 12.32 A. If the panel runs warm — say a packed enclosure near a drive or transformer — size the upstream protection for the derated figure at the expected ambient, not the 30 °C nameplate. Mounting position is any, and the supply can enter from either top or bottom, which simplifies busbar routing in a crowded enclosure. Depth is 77 mm (installation depth 70 mm) and height 90 mm. The IP20 rating applies with the distribution board installed and conductors connected — standard for enclosed panel mounting, not for exposed outdoor use.","metaTitle":"Siemens SENTRON 5SV1313-1GV16 RCBO, 2-Pole, 16 A, Type C, 4.","metaDescription":"Siemens SENTRON 5SV1313-1GV16 RCBO, 2-pole, 16 A rated, Type C tripping, 4.5 kA breaking capacity per EN 60898. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1313-1GV16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"5SV1 RCBO TypeAC 30mA C16 4.5kA 1+N 1MW, Big Pack 12 pcs","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"16 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","at 30 °C / rated value":"16 A","at 40 °C / rated value":"15.2 A","at 45 °C / rated value":"14.72 A","at 50 °C / rated value":"14.24 A","at 55 °C / rated value":"13.76 A","at 60 °C / rated value":"13.28 A","at 65 °C / rated value":"12.8 A","at 70 °C / rated value":"12.32 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","insulation voltage (Ui) / rated value":"253 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265704&mlfb=5SV1313-1GV16"},"ai":{"faq":[{"question":"Where can I buy 5SV1313-1GV16 and how do I get a price?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the difference between 5SV1313-1GV16 and 5SY6013-7?","answer":"The 5SY6013-7 is a Siemens SENTRON MCB (miniature circuit breaker only), not an RCBO — it provides overcurrent protection but no residual current protection. The 5SV1313-1GV16 combines both functions in the same 1 MW footprint. They are not drop-in substitutes; a panel specified around the 5SY6013-7 would need an additional RCCD or RCBO to achieve equivalent residual current protection."},{"question":"What is 5SV1313-1GV16's listed depth?","answer":"The depth is 77 mm, with an installation depth of 70 mm."},{"question":"What is 5SV1313-1GV16's listed width?","answer":"The width is 18 mm, which is 1 modular width unit (1 MW)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1313-1GV16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1313-1GV16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}