{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1313-1KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1313-1KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1313-1KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1313-1KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1313-1KK06, RCBO (Residual Current Circuit Breaker with Overcurrent Protection), 6 A, C-curve, 30 mA, 1P+N, 18 mm wide.","salesMarkdown":"## What bolts in — and what that 30 mA means on the line Siemens SENTRON 5SV1313-1KK06 is a 1P+N RCBO — one module wide (18 mm), rated 6 A at 30 °C with a C-curve trip characteristic and 30 mA residual-current detection. Good for most distribution boards fed from a 10 kA or lower upstream breaker. Mounts in any position, top or bottom feed, one modular width (18 mm). Panel builders: that's one 18 mm slot on the DIN rail. No ventilation gaps needed; it's rated for 75 °C max ambient, but the thermal derating curve below 30 °C is where you plan your load — at 40 °C it's down to 5.64 A, at 50 °C to 5.28 A. If you're loading it near 6 A in a warm cabinet, you'll trip on overload before the RCD sees a fault. ## How it sits against a common panel sibling The 5SY series (e.g. 5SY4106-7CV) is a pure MCB — no residual-current element. The 5SV1313-1KK06 is an RCBO: one device does both overcurrent and earth-fault protection. If your panel was wired around a 5SY MCB plus a separate RCCB, the 5SV1313-1KK06 replaces both in a single 18 mm width. Same DIN footprint, same C-curve, same 6 A rating at 30 °C — but you lose the separate RCD module. Panel builders: check whether your existing busbar or distribution block accommodates the RCBO's wider internal profile; mechanically it clips the same DIN rail. ## IP20, pollution degree 2 — clean indoor gear only IP20 with conductors connected — that's finger-safe when installed in an enclosed distribution board. Not for washdown, not for outdoor exposure. Overvoltage category III means it's rated for fixed-installation downstream of the service entrance — not for plug-in portable gear. ## Residual current type AC — what it catches and what it doesn't Type AC residual current detection means it trips on sinusoidal AC earth faults only. It will NOT detect pulsating DC (Type A) or smooth DC (Type B) residual currents. If your load includes VFDs, switching power supplies, LED drivers, or any half-wave rectified gear, you need a Type A or Type B RCD. Type AC is fine for resistive heating, incandescent lighting, and motor circuits without electronic drives. Know your load harmonics before you spec this.","metaTitle":"Siemens 5SV1313-1KK06 SENTRON RCBO, 6A C-curve 30mA 1P+N","metaDescription":"Siemens 5SV1313-1KK06 SENTRON RCBO, 6A rated, C-curve, 30mA residual current, 4.5kA breaking capacity, 1P+N, 18mm wide. Active lifecycle, available to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1313-1KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type AC 30 mA C6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"6 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Weight With Packaging":"133 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.64 A","at 45 °C rated value":"5.46 A","at 50 °C rated value":"5.28 A","at 55 °C rated value":"5.04 A","at 60 °C rated value":"4.86 A","at 65 °C rated value":"4.62 A","at 70 °C rated value":"4.44 A","Energy Limitation Class":"3","according to EN 61346-2":"F","according to IEC 81346-2":"F","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"4.5 kA","Tripping Fault Current Rated Value":"30 mA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"5 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"0.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027004&mlfb=5SV1313-1KK06"},"ai":{"faq":[{"question":"Where can I buy 5SV1313-1KK06 and get a price?","answer":"Sourced through independent distribution channels against an RFQ. Submit a quote request — availability and current pricing are confirmed at the time of quotation."},{"question":"What is the depth of 5SV1313-1KK06?","answer":"77 mm body depth, plus an installation depth of 70 mm (the distance from DIN rail to the back of the enclosure). Overall height is 90 mm, width is 18 mm (one modular unit)."},{"question":"Will 5SV1313-1KK06 drop into a panel designed for 5SY4106-7CV?","answer":"Mechanically yes — same 18 mm DIN-rail footprint, same C-curve, same 6 A rating. But the 5SV1313-1KK06 is an RCBO (includes earth-fault protection at 30 mA), so it occupies the same single slot that a 5SY MCB does. If the panel had a separate RCD module, you can delete it and use this device alone. Electrically verify busbar compatibility — the RCBO's internal width is the same, but the neutral pole position may differ."},{"question":"What compliance documentation does Siemens provide for 5SV1313-1KK06?","answer":"The product carries EN 60898 rating (4.5 kA breaking capacity) and is designed to IEC 61346-2 / IEC 81346-2 standard letter F. Halogen-free and silicon-free construction. Full RoHS/REACH declarations are standard from Siemens for the SENTRON series — request the manufacturer's declaration of conformity with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1313-1KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1313-1KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}