{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1313-1KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1313-1KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV1313-1KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1313-1KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 13 A, 30 mA, Type AC, tripping characteristic C, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 18 mm width.","salesMarkdown":"It protects final circuits against earth faults (30 mA, Type AC) and overload/short-circuit (13 A, C-curve). Rated breaking capacity is 4.5 kA per EN 60898 and 5 kA per IEC 60947-2 — enough for most domestic and light commercial distribution boards. The 30 mA residual sensitivity (Type AC) catches sinusoidal AC fault currents; it's the standard choice for general-purpose socket circuits and lighting. ## Panel fit and derating Width is 18 mm (1 modular unit), depth 77 mm, installation depth 70 mm. IP20 with the distribution board closed and conductors connected. Current rating is 13 A at 30 °C ambient. Derate linearly: 12.35 A at 40 °C, 11.96 A at 45 °C, 11.57 A at 50 °C, 11.18 A at 55 °C, 10.79 A at 60 °C, 10.4 A at 65 °C, 10.01 A at 70 °C. In a crowded enclosure at 50 °C, plan for 11.5 A continuous load max.","metaTitle":"Siemens SENTRON 5SV1313-1KK13 RCBO, 13 A, 30 mA, Type AC, C-","metaDescription":"Siemens SENTRON 5SV1313-1KK13 RCBO, 13 A rated, 30 mA residual current, Type AC, C-curve, 4.5 kA (EN 60898). Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1313-1KK13","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type AC 30 mA C13","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"13 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","at 30 °C / rated value":"13 A","at 40 °C / rated value":"12.35 A","at 45 °C / rated value":"11.96 A","at 50 °C / rated value":"11.57 A","at 55 °C / rated value":"11.18 A","at 60 °C / rated value":"10.79 A","at 65 °C / rated value":"10.4 A","at 70 °C / rated value":"10.01 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027006&mlfb=5SV1313-1KK13"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1313-1KK13?","answer":"4.5 kA per EN 60898 and 5 kA per IEC 60947-2. Both ratings apply at the rated voltage."},{"question":"What is the temperature derating for this RCBO?","answer":"Rated 13 A at 30 °C. Derates to 12.35 A at 40 °C, 11.57 A at 50 °C, 10.79 A at 60 °C, and 10.01 A at 70 °C. Use the 50 °C column for a typical enclosed panel."},{"question":"Where can I buy 5SV1313-1KK13?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1313-1KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1313-1KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}