{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1313-7KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1313-7KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV1313-7KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1313-7KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SV1313-7KK13, 2-pole, 13 A rated, Type A residual current, C tripping characteristic, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 1 MW wide, IP20.","salesMarkdown":"## Integrator's note — 5SV1313-7KK13 It breaks fault currents up to 4.5 kA per EN 60898 or 5 kA per IEC 60947-2, which covers most residential and light commercial panelboard applications. The 1-module-width (18 mm) footprint saves rail space in crowded enclosures — two of these fit in the same width as a standard 2-pole MCB. Mounting position is unrestricted, and supply can enter from either top or bottom, which simplifies busbar routing in a pre-wired board. ## Temperature derating — what the numbers mean At 40 °C it derates to 12.35 A, at 50 °C to 11.57 A, and at 70 °C to 10.01 A. If the panel runs warm — say 50 °C inside a sealed enclosure — the continuous load should not exceed 11.57 A per pole. This derating curve is published per IEC 60898 and is the same for all C-curve RCBOs in this series; it is not a safety margin but a thermal limit of the bimetal trip element. ## Panel integration checklist Depth 77 mm, height 90 mm — verify enclosure depth clearance (70 mm installation depth plus wiring space). Halogen-free and silicon-free construction meets low-smoke, zero-halogen material requirements for public-access buildings. Touch protection is integral on the line-side terminals.","metaTitle":"Siemens 5SV1313-7KK13 SENTRON RCBO, 13 A, Type A, 2-Pole, 4.","metaDescription":"Siemens 5SV1313-7KK13 SENTRON RCBO, 13 A rated, Type A residual current, 2-pole, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), C-curve, 1 MW wide. Active production, sourced to order. Re","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"77 mm","Poles":"2","Width":"18 mm","Height":"90 mm","Product Status":"Active","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027016&mlfb=5SV1313-7KK13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV1313-7KK13/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1313-7KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1313-7KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}