{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-0KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-0KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-0KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-0KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1316-0KK06 RCBO, 1P+N, B-curve, 6 A at 30 °C, 6 kA (EN 60898) / 35 kA (IEC 60947-2), 50 Hz, IP20, 1 MW unit.","salesMarkdown":"## RCBO for final-circuit protection — 6 A B-curve, 1P+N The 1P+N design switches the phase conductor and monitors the neutral, fitting single-phase sub-distribution boards where space is tight — one modular width unit (18 mm) per pole. The 35 kA rating under 60947-2 gives selectivity headroom upstream of a standard MCB — useful when the RCBO sits close to a transformer or in a main sub-distribution board. Operating frequency is 50 Hz only. Insulation voltage is rated 253 V, surge voltage resistance 4 kV, overvoltage category III, pollution degree 2 — standard for fixed-installation switchgear in a distribution board. ## Temperature derating — real-world current capacity Above that, the RCBO derates linearly: 5.64 A at 40 °C, 5.46 A at 45 °C, 5.28 A at 50 °C, 5.04 A at 55 °C, 4.86 A at 60 °C, 4.62 A at 65 °C, and 4.44 A at 70 °C (–). If the distribution board runs warm — say 50 °C inside a metal enclosure in summer — the usable current drops to 5.28 A. Factor this into the load calculation; a borderline 6 A circuit could nuisance-trip at elevated ambient. Protection class is IP20 with the distribution board installed and conductors connected — not rated for wet or dusty locations. The energy limitation class is 3, meaning it limits let-through energy to a low level, reducing arc-flash risk downstream. Supply can enter top or bottom, which simplifies busbar routing in a crowded panel. The test button requires at least 195 V to operate correctly — ensure the phase-to-neutral voltage is above that threshold for periodic testing.","metaTitle":"Siemens 5SV1316-0KK06 SENTRON RCBO, 6A B-Curve, 6kA/35kA, 1P","metaDescription":"Siemens 5SV1316-0KK06 SENTRON RCBO, 6 A rated at 30 °C, B-curve, 1P+N, 6 kA per EN 60898 / 35 kA per IEC 60947-2. Active production. Sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-0KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type AC 30 mA B6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"133 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.64 A","at 45 °C rated value":"5.46 A","at 50 °C rated value":"5.28 A","at 55 °C rated value":"5.04 A","at 60 °C rated value":"4.86 A","at 65 °C rated value":"4.62 A","at 70 °C rated value":"4.44 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"35 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027018&mlfb=5SV1316-0KK06"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1316-0KK06?","answer":"It is dual-rated: 6 kA according to EN 60898 for domestic/commercial final circuits, and 35 kA according to IEC 60947-2 for industrial distribution. The higher 35 kA rating allows it to be used closer to the transformer where fault currents are higher."},{"question":"What is the temperature derating for 5SV1316-0KK06?","answer":"Rated 6 A at 30 °C, it derates to 5.64 A at 40 °C, 5.28 A at 50 °C, and 4.44 A at 70 °C. Use the 50 °C column (5.28 A) as a practical design limit for a warm distribution board."},{"question":"Will 5SV1316-0KK06 drop into a panel specified around 5SL6120-7 without rewiring?","answer":"Both are 1-module-wide (18 mm) DIN-rail devices, so the physical footprint matches. However, 5SV1316-0KK06 is an RCBO with residual current protection, while 5SL6120-7 is an MCB only. If the panel was wired for an MCB alone, the RCBO adds a neutral connection and a test circuit — verify the neutral bar and wiring space before assuming a drop-in swap."},{"question":"Where can I buy 5SV1316-0KK06 and how is it quoted?","answer":"Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for volume or single-unit requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-0KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-0KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}