{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-1GV16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-1GV16","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-1GV16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-1GV16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 16 A rated, 30 mA residual, type AC, tripping characteristic C, breaking capacity 6 kA per EN 60898 / 10 kA per IEC 60947-2, 18 mm width, halogen-free, current production.","salesMarkdown":"## Siemens 5SV1316-1GV16 — RCBO, 1P+N, 16 A, 30 mA, Type AC, Curve C The neutral pole is switched and protected — the 1P+N configuration means the neutral is opened and closed with the line, not just a solid link. That matters when you need isolation on both conductors for maintenance or fault clearing. At 18 mm wide (1 modular unit), 90 mm tall, and 77 mm deep, this RCBO snaps onto a standard 35 mm DIN rail. The installation depth is 70 mm — the extra 7 mm is the front projection of the toggle and test button. If the enclosure itself is not IP-rated, this device alone does not provide washdown or outdoor protection. The 30 mA residual-current sensitivity (type AC) catches sinusoidal AC earth faults — the common kind from a live conductor touching grounded metal or a person making contact with line and ground. The curve C overcurrent characteristic means the magnetic trip fires at 5 to 10 times rated current (80 to 160 A for this 16 A unit), suitable for loads with moderate inrush like small motors, lighting ballasts, or capacitor banks. For purely resistive loads or long cable runs with no inrush, curve B would be a better selectivity match. Halogen-free and silicon-free construction means the plastic materials do not emit corrosive halogen gases when burned — relevant for installations in confined spaces, public buildings, or areas with sensitive electronic equipment where a fire could cause secondary damage from acidic smoke.","metaTitle":"Siemens SENTRON 5SV1316-1GV16 RCBO, 1P+N 16A 30mA Type AC Cu","metaDescription":"Siemens SENTRON 5SV1316-1GV16 RCBO, 1P+N, 16A rated, 30mA residual, type AC, curve C. Breaking capacity 6kA (EN 60898) / 10kA (IEC 60947-2). 18mm wide, halogen-free. Current produc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-1GV16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"5SV1 RCBO Type AC 30mA C16 6kA 1+N 1MW, Big Pack 12 pcs","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","operational current / at AC / rated value":"16 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265706&mlfb=5SV1316-1GV16"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV1316-1GV16?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"When sourcing 5SV1316-1GV16, what is the closest functional alternative — 5SL6550-7BB?","answer":"The 5SL6550-7BB is a different device: it is a 50 A miniature circuit breaker (MCB) without residual-current protection, while the 5SV1316-1GV16 is a 16 A RCBO with 30 mA RCD. They are not drop-in substitutes. For a direct functional equivalent, look for another 1P+N 16 A 30 mA type AC curve C RCBO in the SENTRON family, but verify the breaking capacity and physical dimensions match your panel design."},{"question":"Will 5SV1316-1GV16 drop into a panel specified around 5SL6550-7BB without rewiring?","answer":"No. The 5SL6550-7BB is a 50 A MCB with no residual-current function; the 5SV1316-1GV16 is a 16 A RCBO with a 30 mA RCD. The current rating, protection function, and neutral switching are all different. The panel would require rewiring and possibly a different upstream protective device to coordinate with the lower 16 A rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-1GV16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-1GV16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}