{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-1KK10","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-1KK10","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-1KK10","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-1KK10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, C-curve 10 A (30 °C), 6 kA per EN 60898, 10 kA per IEC 60947-2, 1 MW width, IP20 with conductors, 50 Hz only.","salesMarkdown":"The Siemens SENTRON 5SV1316-1KK10 is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) in a 1-modular-width (18 mm) housing, rated 10 A at 30 °C with a C-curve tripping characteristic. It combines earth-leakage and overcurrent protection in one DIN-rail device — common in final subcircuits where both fault types must be cleared without a separate RCCB and MCB stack. Rated breaking capacity is 6 kA per EN 60898 and 10 kA per IEC 60947-2 — the higher IEC figure applies when the device is used as a distribution board component with a backup fuse or upstream breaker, giving the panel designer SCCR headroom for industrial panels that need 10 kA at 230 V. The 10 A rating holds at 30 °C ambient; above that the device must be derated linearly to 7.4 A at 70 °C. This matters when the RCBO sits in a crowded enclosure — the 1 MW width (18 mm) limits self-heating, but a row of loaded breakers can raise internal ambient well past 40 °C, where the rating drops to 9.4 A. Installation depth is 70 mm plus the 77 mm overall depth, which fits standard 80 mm deep enclosures. The IP20 rating applies only when the distribution board is installed with connected conductors; the front face is finger-safe, but the terminals are not protected against water ingress.","metaTitle":"Siemens SENTRON 5SV1316-1KK10 RCBO, 10A C-curve, 1P+N, 6kA E","metaDescription":"Siemens SENTRON 5SV1316-1KK10 RCBO, 10A rated at 30°C, C-curve, 1P+N, 6kA per EN 60898 / 10kA per IEC 60947-2. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-1KK10","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type AC 30 mA C10","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"133 g","at 30 °C rated value":"10 A","at 40 °C rated value":"9.4 A","at 45 °C rated value":"9.1 A","at 50 °C rated value":"8.8 A","at 55 °C rated value":"8.4 A","at 60 °C rated value":"8.1 A","at 65 °C rated value":"7.7 A","at 70 °C rated value":"7.4 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027025&mlfb=5SV1316-1KK10"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1316-1KK10?","answer":"6 kA per EN 60898 and 10 kA per IEC 60947-2 at 230 V AC."},{"question":"What is the thermal derating for 5SV1316-1KK10?","answer":"Rated 10 A at 30 °C, derated to 9.4 A at 40 °C, 8.8 A at 50 °C, 8.1 A at 60 °C, and 7.4 A at 70 °C."},{"question":"Where can I buy 5SV1316-1KK10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-1KK10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-1KK10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}