{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-4KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-4KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-4KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-4KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO compact, 1P+N, 6 kA per EN 60898, type F, 30 mA, C6 characteristic, 1 MW wide, 5SV1316-4KK06.","salesMarkdown":"## RCBO compact 1P+N — type F, 30 mA, C6 It combines a 1P+N pole configuration with a C tripping characteristic, rated at 6 kA per EN 60898 and 10 kA per IEC 60947-2. The type F residual current sensitivity is 30 mA, designed for circuits where smooth DC residual currents or mixed-frequency waveforms may be present — common on variable-speed drives, washing machines, and other inverter-fed loads that a standard AC type might miss. The supply can enter from either top or bottom, and the mounting position is unrestricted. Type F residual current detection (30 mA) is specified for circuits where smooth DC components up to 10 mA or mixed frequencies up to 1 kHz may be present. This covers single-phase inverter-fed loads (washing machines, heat pumps, some EV chargers) that a type A or AC device might not detect reliably. Energy limitation class 3 means the device limits let-through energy (I²t) to the lowest level in its class, reducing stress on downstream cables and equipment during a fault. The 3 kA surge current withstand (8/20 μs) and 4 kV surge voltage resistance confirm it survives typical lightning-induced transients without damage. ## Integration notes At 18 mm (1 MW) wide, it occupies the same footprint as a single-pole MCB, leaving room in the panel for additional circuits. The supply can be fed from top or bottom, simplifying busbar routing in pre-wired boards.","metaTitle":"Siemens 5SV1316-4KK06 SENTRON RCBO, 1P+N, 6 kA, Type F, 30 m","metaDescription":"Siemens SENTRON 5SV1316-4KK06 RCBO, 1P+N, 6 kA (EN 60898), 10 kA (IEC 60947-2), Type F, 30 mA, C6. Active production. Sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-4KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type F 30 mA C6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Super resistant K","Weight With Packaging":"133 g","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"3 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"0.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027032&mlfb=5SV1316-4KK06"},"ai":{"faq":[{"question":"Where can I buy 5SV1316-4KK06 and how is it quoted?","answer":"The 5SV1316-4KK06 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source to 5SV1316-4KK06?","answer":"The Siemens 5SY4116-7CV is a related MCB in the same SENTRON family, but it is a miniature circuit breaker without residual current protection. The 5SV1316-4KK06 is an RCBO combining overcurrent and earth-leakage protection in one unit. They are not drop-in substitutes; the 5SV1316-4KK06 provides type F 30 mA RCD functionality that the 5SY4116-7CV lacks."},{"question":"What compliance documentation does Siemens provide for 5SV1316-4KK06?","answer":"The 5SV1316-4KK06 is rated per EN 60898 (6 kA) and IEC 60947-2 (10 kA). It is halogen-free and silicon-free. The manufacturer provides standard declarations of conformity and CE marking; specific documentation (RoHS, REACH, UL) should be requested at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-4KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-4KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}