{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-4KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-4KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-4KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-4KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1316-4KK13 RCBO, 1P+N, tripping characteristic C, 13 A at 30 °C, 10 kA per IEC 60947-2, super-resistant K design, 18 mm wide, DIN-rail mount.","salesMarkdown":"It combines a C-curve MCB and an RCD in a single 18 mm wide module, rated 13 A at 30 °C and 12.35 A at 40 °C, with a 10 kA breaking capacity per IEC 60947-2 and 6 kA per EN 60898. The super-resistant K variant means the internal components are halogen-free and silicon-free, suited for environments where outgassing or contamination from standard plastics is a concern, such as clean rooms or food-processing areas. At a 30 °C ambient the full 13 A is available; at 40 °C derate to 12.35 A, at 50 °C to 11.57 A, at 60 °C to 10.79 A, and at 70 °C to 10.01 A. The 10 kA SCCR per IEC 60947-2 covers most domestic and commercial fault levels; the 6 kA per EN 60898 is the lower bound for residential panels. Supply can feed from top or bottom, and mounting position is any — no orientation restrictions in the panel.","metaTitle":"Siemens 5SV1316-4KK13 SENTRON RCBO, 1P+N, C-curve, 13 A, 10","metaDescription":"Siemens 5SV1316-4KK13 SENTRON RCBO, 1P+N, C-curve, 13 A at 30 °C, 10 kA per IEC 60947-2. Active production. Quoted to order. DIN-rail mount, 18 mm wide.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-4KK13","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type F 30 mA C13","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Super resistant K","Weight With Packaging":"133 g","at 30 °C rated value":"13 A","at 40 °C rated value":"12.35 A","at 45 °C rated value":"11.96 A","at 50 °C rated value":"11.57 A","at 55 °C rated value":"11.18 A","at 60 °C rated value":"10.79 A","at 65 °C rated value":"10.4 A","at 70 °C rated value":"10.01 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"3 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027034&mlfb=5SV1316-4KK13"},"ai":{"faq":[{"question":"Where can I buy 5SV1316-4KK13 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the depth of 5SV1316-4KK13?","answer":"The listed depth is 77 mm, with a 70 mm installation depth behind the panel face."},{"question":"What is the width of 5SV1316-4KK13?","answer":"18 mm, which is 1 modular unit on standard DIN rail."},{"question":"Will 5SV1316-4KK13 drop into a panel specified around 5SL6006-7 without rewiring?","answer":"No — the 5SL6006-7 is a different class (MCB only, no RCD), and the 5SV1316-4KK13 is an RCBO with different internal wiring for the neutral. Physical dimensions are similar (18 mm wide), but the circuit connections differ."},{"question":"What compliance documentation does Siemens provide for 5SV1316-4KK13?","answer":"Halogen-free and silicon-free declarations, plus RoHS and REACH compliance documentation are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-4KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-4KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}