{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-6KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-6KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-6KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-6KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1316-6KK16 RCBO, 1P+N, 16 A rated current at 30 °C, 6 kA breaking capacity per EN 60898, Type B tripping characteristic, instantaneous design.","salesMarkdown":"## Rated current and breaking capacity — what governs the BOM fit The 5SV1316-6KK16: That dual rating means it covers residential and light commercial panels (EN 60898) and industrial distribution boards (IEC 60947-2) with a single device — no need to swap breakers when the installation standard changes. The Type B tripping characteristic trips instantaneously at 3–5× rated current, designed for resistive and inductive loads without high inrush — lighting circuits, heating elements, general socket outlets. The 1P+N design protects one phase and switches the neutral without monitoring it. One modular unit wide (18 mm) with a 77 mm depth and 90 mm height — fits standard DIN-rail enclosures without oversizing the cabinet. Supply can enter from either top or bottom, which simplifies panel layout when busbars run on one side. IP20 protection applies once the distribution board is installed with connected conductors. ## Ambient temperature derating — real-world current limits","metaTitle":"Siemens 5SV1316-6KK16 RCBO, 1P+N, 16 A, 6 kA, Type B","metaDescription":"Siemens SENTRON 5SV1316-6KK16 RCBO, 1P+N, 16 A rated, 6 kA breaking capacity per EN 60898, Type B trip curve. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-6KK16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type A 30 mA B16","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"133 g","at 30 °C rated value":"16 A","at 40 °C rated value":"15.2 A","at 45 °C rated value":"14.88 A","at 50 °C rated value":"14.4 A","at 55 °C rated value":"14.08 A","at 60 °C rated value":"13.6 A","at 65 °C rated value":"13.28 A","at 70 °C rated value":"12.8 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"15 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$38.10","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027039&mlfb=5SV1316-6KK16"},"ai":{"faq":[{"question":"Is 5SV1316-6KK16 a Type A RCBO?","answer":"No, the 5SV1316-6KK16 is a Type B RCBO (tripping characteristic B per). Type A RCBOs detect pulsed DC residual currents; Type B detects smooth DC residual currents. This device is Type B, suitable for loads with AC and smooth DC fault currents."},{"question":"What is the difference between Type A and Type AC RCBO?","answer":"Type AC RCBOs detect only sinusoidal AC residual currents. Type A adds detection of pulsed DC residual currents (e.g., from rectifiers or switching power supplies). Type B adds smooth DC residual currents. The 5SV1316-6KK16 is Type B, covering all three."},{"question":"Can I use a 1P+N RCBO for a lighting circuit?","answer":"Yes, a 1P+N RCBO like the 5SV1316-6KK16 is suitable for single-phase lighting circuits. The Type B characteristic handles the inrush of LED drivers and electronic ballasts without nuisance tripping, provided the 16 A rating at the derated ambient temperature is not exceeded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-6KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-6KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}