{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-6LK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-6LK13","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-6LK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-6LK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1316-6LK13 RCBO, 1-pole+N, 13 A rated at 30 °C, B tripping characteristic, 6 kA per EN 60898, 15 kA per IEC 60947-2, short-time delayed G / super resistant K design, halogen-free, silicon-free, IP20.","salesMarkdown":"The Siemens 5SV1316-6LK13 is a SENTRON RCBO — a combined residual-current and overcurrent protective device — in a 1-pole+N configuration (switching the line, monitoring the neutral) that fits a single 18 mm modular-width slot on a DIN rail. Energy limitation class 3 means the RCBO lets through relatively low let-through energy during a fault, which helps achieve selectivity with upstream devices and reduces stress on downstream wiring. ## Thermal derating and installation constraints The 13 A rating is at 30 °C ambient; the device must be derated in warmer enclosures — at 40 °C it carries 12.35 A, at 50 °C it carries 11.57 A, and at 70 °C it carries 10.01 A. This derating curve is built into the design and should be applied when grouping multiple RCBOs in a panel to avoid nuisance tripping from internal heat buildup. IP20 protection applies when installed in a distribution board with conductors connected — the device itself is not sealed against dust ingress or moisture, so it must live inside a closed enclosure. ## Environmental and compliance profile","metaTitle":"Siemens 5SV1316-6LK13 SENTRON RCBO, 1P+N, 13A, B Curve, 6kA","metaDescription":"Siemens SENTRON 5SV1316-6LK13 RCBO, 1P+N, 13A rated at 30°C, B tripping curve, 6kA (EN 60898) / 15kA (IEC 60947-2). Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50/60 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Short-time delayed G, super resistant K","Weight With Packaging":"133 g","at 30 °C rated value":"13 A","at 40 °C rated value":"12.35 A","at 45 °C rated value":"11.96 A","at 50 °C rated value":"11.57 A","at 55 °C rated value":"11.18 A","at 60 °C rated value":"10.79 A","at 65 °C rated value":"10.4 A","at 70 °C rated value":"10.01 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"15 kA","Surge Current Resistance At (8/20) μS":"3 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027042&mlfb=5SV1316-6LK13","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV1316-6LK13/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1316-6LK13?","answer":"6 kA per EN 60898 and 15 kA per IEC 60947-2."},{"question":"Where can I buy 5SV1316-6LK13 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"Will 5SV1316-6LK13 drop into a panel specified around 5SY4116-7CV without rewiring?","answer":"Both are 1-module-wide (18 mm) DIN-rail devices, so the physical footprint is the same, but 5SV1316-6LK13 is an RCBO with combined residual-current and overcurrent protection, while 5SY4116-7CV is a plain MCB — the wiring differs because the RCBO requires a neutral connection and has a test button circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-6LK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-6LK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}