{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-7GV06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-7GV06","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-7GV06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-7GV06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SV1316-7GV06, 2-pole 1P+N, 6 A rated, Type A residual current, C tripping characteristic, 10 kA IEC 60947-2, 18 mm wide.","salesMarkdown":"It occupies a single modular width (18 mm) on the DIN rail, making it a tight fit for densely packed sub-distribution boards where every slot counts. The 6 A C-curve handles moderate inrush from small motor or lighting loads without nuisance tripping. Type A residual current detection covers pulsating DC faults from rectified loads — common in modern equipment with switched-mode power supplies or variable-speed drives. The 1P+N configuration switches the phase only, leaving the neutral solid; verify your distribution design expects a switched-phase, solid-neutral RCBO before specifying. Current-production status per the manufacturer. The 77 mm depth fits flush in most enclosure depths, leaving cable management space behind the gland plate. IP20 rated with the distribution board installed and conductors connected — not for open-panel or washdown environments. The higher IEC figure gives headroom for industrial panels with higher prospective fault currents. Derate the thermal rating when ambient exceeds 30 °C — at 50 °C the continuous current drops to 5.28 A, and at 70 °C to 4.44 A. Halogen-free and silicon-free construction suits clean manufacturing environments.","metaTitle":"Siemens 5SV1316-7GV06 SENTRON RCBO, 6 A, Type A, C-curve","metaDescription":"Siemens 5SV1316-7GV06 SENTRON RCBO, 6 A rated, Type A residual current, C tripping characteristic, 10 kA breaking capacity per IEC 60947-2. Active production. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"6 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","at 30 °C / rated value":"6 A","at 40 °C / rated value":"5.64 A","at 45 °C / rated value":"5.46 A","at 50 °C / rated value":"5.28 A","at 55 °C / rated value":"5.04 A","at 60 °C / rated value":"4.86 A","at 65 °C / rated value":"4.62 A","at 70 °C / rated value":"4.44 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265710&mlfb=5SV1316-7GV06","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV1316-7GV06/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV1316-7GV06 and get a price?","answer":"This part is available to quote against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time."},{"question":"What is the difference between 5SV1316-7GV06 and the peer 5SY6006-7?","answer":"The 5SY6006-7 is a Siemens SENTRON MCB (overcurrent protection only) with no residual current protection. The 5SV1316-7GV06 adds Type A RCD functionality in a 1P+N RCBO package. If your circuit requires ground-fault protection, the MCB alone will not meet the requirement."},{"question":"What is the depth of 5SV1316-7GV06?","answer":"The listed depth is 77 mm with an installation depth of 70 mm. This fits standard 80 mm deep distribution boards with room for cable management."},{"question":"What compliance documentation does Siemens provide for 5SV1316-7GV06?","answer":"The RCBO is designed to EN 60898 and IEC 60947-2 standards. It carries Overvoltage Category III and Pollution Degree 2 ratings. The manufacturer typically provides CE, UKCA, and EAC declarations, plus RoHS and REACH compliance documentation on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-7GV06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-7GV06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}