{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1316-7KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1316-7KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1316-7KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1316-7KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1316-7KK06 RCBO, 1P+N, C-curve, rated 6 A at 30 °C, breaking capacity 10 kA per IEC 60947-2, 1 MW (18 mm) wide, 77 mm depth.","salesMarkdown":"## What the C-curve and 10 kA mean for your panel The Siemens 5SV1316-7KK06 is a 1P+N RCBO from the SENTRON family — a combined residual-current and overcurrent device that saves a DIN-width slot compared to a separate RCCB plus MCB pair. The C-curve tripping characteristic means it holds up to 5–10× rated current for short surges (motor inrush, capacitor charging) but trips magnetically on a hard fault. At 6 A rated current at 30 °C, it's sized for lighting subcircuits, small pumps, or control transformers in a 230 V AC single-phase panel. ## Derating and temperature — don't let a warm cabinet trip you up The 5SV1316-7KK06 carries a full derating table from 30 °C to 70 °C (–). At 30 °C it's rated 6 A; at 50 °C that drops to 5.28 A; at 70 °C it's 4.44 A. If your panel runs warm — say 50 °C inside a non-ventilated enclosure — you can't load this breaker to its 30 °C nameplate. Size the circuit so the continuous load stays under the derated figure for your ambient. ## Mounting and installation — one MW slot, any orientation At 18 mm wide (1 modular width,) and 77 mm deep, this RCBO fits a standard DIN-rail enclosure with 70 mm installation depth. The supply can land on either top or bottom terminals, so you can wire it into a pre-bussed panel without re-routing. Mounting position is any, which helps in tight enclosures where you need to rotate the device for wire access.","metaTitle":"Siemens 5SV1316-7KK06 RCBO, C-curve 6A, 1P+N, 10kA IEC","metaDescription":"Siemens SENTRON 5SV1316-7KK06 RCBO, 1P+N, C-curve, 6A at 30°C, 10kA breaking per IEC 60947-2, 1 MW wide. Active production, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1316-7KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type A 30 mA C6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"133 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.64 A","at 45 °C rated value":"5.46 A","at 50 °C rated value":"5.28 A","at 55 °C rated value":"5.04 A","at 60 °C rated value":"4.86 A","at 65 °C rated value":"4.62 A","at 70 °C rated value":"4.44 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$215.34 – $272.39","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/50e590cfc611663d86f4d47f5958db69.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027050&mlfb=5SV1316-7KK06"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1316-7KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1316-7KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}