{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1613-6KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1613-6KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1613-6KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1613-6KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole (1P+N), Type A, 6 A, B-curve, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 1 MW, 18 mm wide.","salesMarkdown":"## RCBO for mixed resistive and motor loads The Siemens 5SV1613-6KK06 is a SENTRON RCBO combining a Type A residual current device with a B-curve MCB in a single 1-module-width (18 mm) package. It protects against earth faults with DC-sensitive detection (Type A) and overcurrent/short-circuit with a 6 A B-curve thermal-magnetic trip. The 4.5 kA breaking capacity per EN 60898 and 5 kA per IEC 60947-2 cover most residential and light commercial panel fault levels. ## Sizing and derating in the panel At 30 °C the unit is rated a full 6 A. Above that, derate linearly: 5.64 A at 40 °C, 5.28 A at 50 °C, 4.86 A at 60 °C, and 4.44 A at 70 °C. In a crowded enclosure where ambient hits 50 °C, plan for 5.28 A continuous — not the 6 A label. ## Mounting and wiring flexibility Mounts in any position — no derating for orientation. The 2-pole (1P+N) design switches the line conductor only; the neutral is switched through the RCD. IP20 protection applies once the distribution board is installed and conductors are connected.","metaTitle":"Siemens 5SV1613-6KK06 SENTRON RCBO 2-pole Type A 6 A B-curve","metaDescription":"Siemens 5SV1613-6KK06 SENTRON RCBO, 2-pole (1P+N), Type A, 6 A, B-curve, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2). Current production. Sourced to order. Get a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1613-6KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type A 300 mA B6","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"6 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","at 30 °C / rated value":"6 A","at 40 °C / rated value":"5.64 A","at 45 °C / rated value":"5.46 A","at 50 °C / rated value":"5.28 A","at 55 °C / rated value":"5.04 A","at 60 °C / rated value":"4.86 A","at 65 °C / rated value":"4.62 A","at 70 °C / rated value":"4.44 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027074&mlfb=5SV1613-6KK06"},"ai":{"faq":[{"question":"Where can I buy the 5SV1613-6KK06 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"What is the depth of the 5SV1613-6KK06?","answer":"The listed depth is 77 mm, with an installation depth of 70 mm."},{"question":"What is the width of the 5SV1613-6KK06?","answer":"The width is 18 mm, which is 1 modular width unit."},{"question":"Will the 5SV1613-6KK06 drop into a panel specified around the 5SL3116-6MB without rewiring?","answer":"Both are 1-module-width (18 mm) DIN-rail RCBOs, but the 5SL3116-6MB is a different series with its own wiring and accessory layout. Verify the terminal positions and neutral bar arrangement against the existing panel layout before assuming a drop-in fit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1613-6KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1613-6KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}