{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1613-6KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1613-6KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV1613-6KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1613-6KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV1613-6KK13 RCBO, 2-pole, 13 A rated, 30 mA Type A residual current, B-curve, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 18 mm wide, IP20.","salesMarkdown":"The Siemens SENTRON 5SV1613-6KK13 is a 2-pole residual-current circuit breaker with overcurrent protection (RCBO), combining a 13 A thermal-magnetic overcurrent trip (B-curve) and a 30 mA Type A residual-current unit in one 18 mm-wide module. It is rated for 50 Hz networks, with a breaking capacity of 4.5 kA per EN 60898 and 5 kA per IEC 60947-2. The Type A residual-current detection handles pulsating DC fault currents up to 30 mA, covering the majority of modern electronic loads (switched-mode power supplies, variable-speed drives, lighting ballasts) that a pure AC-sensitive RCD would miss. ## Temperature derating — what the 13 A rating means in a warm panel The 13 A rating holds only at 30 °C ambient. At 40 °C it derates to 12.35 A, at 50 °C to 11.57 A, and at 70 °C to 10.01 A. In a typical enclosed distribution board where internal temperatures regularly reach 45–50 °C, the effective continuous current is closer to 12 A than 13 A. Factor this into your load schedule if the RCBO sits near other heat sources or in a compact enclosure. Occupies a single 18 mm modular-width slot on a DIN rail. The 77 mm depth and 90 mm height fit standard distribution boards; the 70 mm installation depth accounts for the rear projection behind the rail. IP20 protection applies once the distribution board is installed and conductors are connected.","metaTitle":"Siemens 5SV1613-6KK13 SENTRON RCBO, 13 A, 30 mA Type A, 2-po","metaDescription":"Siemens 5SV1613-6KK13 SENTRON RCBO, 13 A rated, 30 mA Type A residual current, 2-pole, 4.5 kA (EN 60898), 5 kA (IEC 60947-2), B-curve, 18 mm wide. Current production — sourced to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1613-6KK13","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type A 300 mA B13","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"13 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","at 30 °C / rated value":"13 A","at 40 °C / rated value":"12.35 A","at 45 °C / rated value":"11.96 A","at 50 °C / rated value":"11.57 A","at 55 °C / rated value":"11.18 A","at 60 °C / rated value":"10.79 A","at 65 °C / rated value":"10.4 A","at 70 °C / rated value":"10.01 A","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"300 mA","insulation voltage (Ui) / rated value":"253 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027076&mlfb=5SV1613-6KK13"},"ai":{"faq":[{"question":"What is the rated breaking capacity of 5SV1613-6KK13?","answer":"4.5 kA per EN 60898 and 5 kA per IEC 60947-2."},{"question":"What residual current types does this RCBO detect?","answer":"Type A — it detects sinusoidal AC fault currents and pulsating DC fault currents up to 30 mA."},{"question":"Where can I buy 5SV1613-6KK13 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1613-6KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1613-6KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}