{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1613-6KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1613-6KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV1613-6KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1613-6KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 16 A rated, 300 mA residual, Type A, 4.5 kA, 18 mm wide.","salesMarkdown":"## What this RCBO is and what it does The Siemens SENTRON 5SV1613-6KK16 is a 1P+N RCBO — a combined residual-current device and miniature circuit breaker in a single 18 mm wide module. It's rated 16 A with a B tripping characteristic, meaning it protects against overloads and short circuits in circuits with resistive and light inductive loads like lighting or small motor starters. The 300 mA residual-current element is Type A, so it detects sinusoidal AC faults plus pulsating DC fault currents — common in electronics-heavy circuits like VFDs, switch-mode supplies, or modern appliances. The breaking capacity is 4.5 kA per EN 60898 and IEC 60947-2, which covers most domestic and light commercial distribution boards. ## Where it fits — panel and environment At 18 mm wide (one modular unit), this RCBO snaps onto a standard DIN rail and sits in a distribution board. The depth is 77 mm with a 70 mm installation depth, so it fits most standard enclosures without bottoming out on the backplane. It's rated IP20 once installed with conductors connected — fine for enclosed panels, not for washdown or outdoor exposure. The operating temperature range is -40 °C to 75 °C, which covers unheated utility rooms and hot switchgear cabinets. Mounting position is any, so it's fine upright, sideways, or upside-down in a crowded panel. The neutral conductor is switched internally, so you don't need a separate neutral bar connection downstream.","metaTitle":"Siemens SENTRON 5SV1613-6KK16 RCBO, 16 A, 300 mA, Type A, 4.","metaDescription":"Siemens SENTRON 5SV1613-6KK16 RCBO, 1P+N, 16 A rated, 300 mA residual, Type A, 4.5 kA breaking capacity. Current-production part sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1613-6KK16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type A 300 mA B16","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","Number Of Modular Width Units":"1","Tripping Characteristic Class":"B","acc. to EN 60898 / rated value":"4.5 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"4.5 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","operational current / at AC / rated value":"16 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027077&mlfb=5SV1613-6KK16"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1613-6KK16?","answer":"The breaking capacity is 4.5 kA per both EN 60898 and IEC 60947-2, which is standard for domestic and light commercial distribution boards."},{"question":"What is the difference between 5SV1613-6KK16 and 5SY6002-7KL?","answer":"The 5SY6002-7KL is a different class of device — a miniature circuit breaker (MCB) without residual-current protection. The 5SV1613-6KK16 is an RCBO that combines overcurrent and earth-fault protection in one module. They are not drop-in substitutes without rewiring."},{"question":"Where can I buy 5SV1613-6KK16?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1613-6KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1613-6KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}