{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1613-7KK02","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1613-7KK02","canonicalUrl":"https://aoctrl.com/siemens/5SV1613-7KK02","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1613-7KK02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 5SV1613-7KK02, 2 A rated, C characteristic, 300 mA residual current Type A, 1P+N, 4.5 kA breaking capacity, 1 MW wide, IP20.","salesMarkdown":"It combines a C-curve miniature circuit breaker (MCB) for overcurrent protection with a 300 mA Type A residual current device (RCD) for earth fault protection, all in one device that snaps onto a DIN rail. The 300 mA residual current rating is a standard for general socket-outlet protection in commercial or residential final circuits, not the 30 mA required for personal shock protection. The device is rated for 50 Hz systems only, with a Type A residual current characteristic — it detects sinusoidal AC residual currents plus pulsating DC residual currents, covering most modern electronic loads like switched-mode power supplies and variable-speed drives that generate pulsating fault currents. Installation depth is 70 mm — check your enclosure depth if using a shallow distribution board. Supply can enter from either top or bottom, so no need to flip the busbar arrangement. The IP20 rating applies when installed in a distribution board with connected conductors — it's not a standalone outdoor device. Rated 2 A at 30 °C ambient, but derates linearly to 1.6 A at 70 °C.","metaTitle":"Siemens SENTRON 5SV1613-7KK02 RCBO, 2 A, C Curve, 300 mA, 1P","metaDescription":"Siemens SENTRON 5SV1613-7KK02 RCBO, 2 A rated, C tripping characteristic, 300 mA residual current, Type A, 4.5 kA breaking capacity, 1 MW wide. Current lifecycle. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1613-7KK02","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type A 300 mA C2","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","at AC / rated value":"2 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Energy Limitation Class":"3","Weight / With Packaging":"133 g","according to EN 61346-2":"F","at 30 °C / rated value":"2 A","at 40 °C / rated value":"1.9 A","at 45 °C / rated value":"1.86 A","at 50 °C / rated value":"1.8 A","at 55 °C / rated value":"1.76 A","at 60 °C / rated value":"1.7 A","at 65 °C / rated value":"1.66 A","at 70 °C / rated value":"1.6 A","according to IEC 81346-2":"F","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","according to EN 60898 / rated value":"4.5 kA","Tripping Fault Current / Rated Value":"300 mA","insulation voltage (Ui) / rated value":"253 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","according to IEC 60947-2 / rated value":"5 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027078&mlfb=5SV1613-7KK02"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1613-7KK02?","answer":"Rated 4.5 kA according to EN 60898, which is the standard for miniature circuit breakers in household and similar installations."},{"question":"What is the residual current rating and type?","answer":"300 mA, Type A — detects sinusoidal AC and pulsating DC residual currents, suitable for circuits with electronic loads."},{"question":"Where can I buy 5SV1613-7KK02?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Will 5SV1613-7KK02 drop into a panel specified for 5SU9304-1KK32?","answer":"Both are 1 MW wide RCBOs from the SENTRON family, but the 5SU9304-1KK32 is a different variant — check the rated current, residual current, and characteristic before substituting. The 5SV1613-7KK02 is 2 A, C curve, 300 mA Type A; the 5SU9304-1KK32 may differ in these ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1613-7KK02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1613-7KK02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}