{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1613-7KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1613-7KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV1613-7KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1613-7KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole, 16 A rated current, 300 mA residual current, Type A, tripping characteristic C, 4.5 kA breaking capacity per EN 60898, 1 MW width, IP20.","salesMarkdown":"## RCBO for final-circuit protection It occupies a single modular width (18 mm) on the DIN rail, making it a compact choice for final circuits in residential and commercial distribution boards where both earth leakage and overload/short-circuit protection are required in one device. The 16 A rating holds at 30 °C ambient; at 40 °C the continuous current derates to 15.2 A, and at 50 °C to 14.24 A. At the maximum operating temperature of 75 °C the device is rated at 12.32 A. Minimum storage temperature is -40 °C. Mounting position is unrestricted, and the supply can enter from either top or bottom. ## Integration notes","metaTitle":"Siemens SENTRON 5SV1613-7KK16 RCBO, 16 A, 300 mA, Type A, 1","metaDescription":"Siemens SENTRON 5SV1613-7KK16 RCBO, 2-pole, 16 A rated, 300 mA residual current, Type A, 4.5 kA breaking capacity per EN 60898. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1613-7KK16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 4.5 kA type A 300 mA C16","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","at AC / rated value":"16 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Energy Limitation Class":"3","Weight / With Packaging":"133 g","according to EN 61346-2":"F","at 30 °C / rated value":"16 A","at 40 °C / rated value":"15.2 A","at 45 °C / rated value":"14.72 A","at 50 °C / rated value":"14.24 A","at 55 °C / rated value":"13.76 A","at 60 °C / rated value":"13.28 A","at 65 °C / rated value":"12.8 A","at 70 °C / rated value":"12.32 A","according to IEC 81346-2":"F","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","Product Feature / Touch Protection":"Yes","according to EN 60898 / rated value":"4.5 kA","Tripping Fault Current / Rated Value":"300 mA","insulation voltage (Ui) / rated value":"253 V","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Voltage Resistance / Rated Value":"4 000 V","according to IEC 60947-2 / rated value":"5 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Surge Current Resistance / At (8/20) μS":"1 kA","Type Of Voltage / Of The Operating Voltage":"AC","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027083&mlfb=5SV1613-7KK16"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SV1613-7KK16?","answer":"Rated breaking capacity is 4.5 kA per EN 60898."},{"question":"What is the residual current rating and type?","answer":"Residual tripping current is 300 mA, Type A (sensitive to pulsating DC and AC residual currents)."},{"question":"Where can I buy 5SV1613-7KK16 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1613-7KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1613-7KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}