{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1616-1KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1616-1KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV1616-1KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1616-1KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 2-pole (1P+N), 16 A rated current, 300 mA residual current, Type AC, C-curve, breaking capacity 6 kA (EN 60898) / 10 kA (IEC 60947-2), 1 MW width.","salesMarkdown":"The Siemens SENTRON 5SV1616-1KK16 is a 2-pole (1P+N) residual-current circuit breaker with overcurrent protection (RCBO) rated at 16 A operational current and 300 mA residual tripping current, Type AC, with a C tripping characteristic. It's designed for 50 Hz AC systems at 230 V and fits a single modular-width unit (18 mm) on a DIN rail. The 300 mA residual sensitivity (Type AC) covers sinusoidal AC earth faults — common for general-purpose circuits where no DC or pulsating fault content is expected. The 5SV1616-1KK16 is part of the Siemens SENTRON range, a widely used protection component line. For a BOM freeze or second-source gate, the closest functional peer is the 5SL6550-7BB — but verify the pole count, residual current, and curve before substituting, as the 5SL6550-7BB is a different variant. Width is 18 mm (1 modular unit), depth 77 mm, height 90 mm, with an installation depth of 70 mm. The neutral conductor is switched internally (1P+N).","metaTitle":"Siemens SENTRON 5SV1616-1KK16 RCBO, 16 A, 300 mA, Type AC, C","metaDescription":"Siemens SENTRON 5SV1616-1KK16 RCBO, 2-pole (1P+N), 16 A rated current, 300 mA residual current, Type AC, C-curve, 6 kA (EN 60898) / 10 kA (IEC 60947-2) breaking capacity. In curren","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1616-1KK16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type AC 300 mA C16","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","acc. to IEC 81346-2":"F","at AC / rated value":"230 V","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"AC","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","Weight / With Packaging":"133 g","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"Either top or bottom","Number Of Poles / With Protection":"1","acc. to IEC 60947-2 / rated value":"10 kA","Product Feature / Touch Protection":"Yes","Tripping Fault Current / Rated Value":"300 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Influence Of The Surrounding Temperature":"Max. 95% humidity","operational current / at AC / rated value":"16 A","Product Function / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027095&mlfb=5SV1616-1KK16"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV1616-1KK16?","answer":"Submit an RFQ through this listing. Pricing and availability are confirmed at quote time; we source through independent distribution channels."},{"question":"What is the closest functional second-source for 5SV1616-1KK16?","answer":"The 5SL6550-7BB is a functional peer in the same SENTRON family, but verify the pole count, residual current rating, and curve before substituting — they are not drop-in identical."},{"question":"What are the key specs of 5SV1616-1KK16?","answer":"2-pole (1P+N) RCBO, 16 A rated current, 300 mA residual, Type AC, C-curve, breaking capacity 6 kA (EN 60898) / 10 kA (IEC 60947-2), 1 MW width (18 mm), depth 77 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1616-1KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1616-1KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}