{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1616-6KK16","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1616-6KK16","canonicalUrl":"https://aoctrl.com/siemens/5SV1616-6KK16","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1616-6KK16","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 16 A at 30 °C, B tripping characteristic, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 230 V AC, 50 Hz, 1 MW unit, IP20.","salesMarkdown":"The Siemens 5SV1616-6KK16 is a SENTRON RCBO in a 1P+N, 2-pole configuration. It combines a 16 A overcurrent trip (B characteristic) with residual current detection in a single 18 mm wide, 1-module-width unit. Rated 16 A at 30 °C, the part derates to 12.8 A at 70 °C — a 20 % loss that matters if the panel runs hot. ## Panel integration The 18 mm width (1 modular unit) and 77 mm depth fit standard distribution board cutouts. Supply can enter from top or bottom.","metaTitle":"Siemens 5SV1616-6KK16 SENTRON RCBO, 16 A, B Curve, 6 kA","metaDescription":"Siemens 5SV1616-6KK16 SENTRON RCBO, 1P+N, 16 A at 30 °C, B tripping characteristic, 6 kA breaking capacity per EN 60898. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1616-6KK16","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type A 300 mA B16","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Weight With Packaging":"133 g","at 30 °C rated value":"16 A","at 40 °C rated value":"15.2 A","at 45 °C rated value":"14.88 A","at 50 °C rated value":"14.4 A","at 55 °C rated value":"14.08 A","at 60 °C rated value":"13.6 A","at 65 °C rated value":"13.28 A","at 70 °C rated value":"12.8 A","Energy Limitation Class":"3","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"B","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"15 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027101&mlfb=5SV1616-6KK16"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1616-6KK16","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1616-6KK16 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}