{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV1616-7KK06","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV1616-7KK06","canonicalUrl":"https://aoctrl.com/siemens/5SV1616-7KK06","factsUrl":"https://aoctrl.com/api/mcp/products/5SV1616-7KK06","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCBO, 1P+N, 6 A rated, C characteristic, 300 mA residual current Type A, 6 kA per EN 60898, instantaneous design, 18 mm width, IP20.","salesMarkdown":"The Siemens SENTRON 5SV1616-7KK06 is a 1P+N RCBO (residual current circuit breaker with overcurrent protection) in an 18 mm single-module width, combining a C-curve thermal-magnetic overcurrent trip at 6 A with a 300 mA Type A residual current detection element. Type A residual current detection means it trips on sinusoidal AC fault currents and also on pulsating DC fault currents — the standard requirement for circuits with single-phase rectified loads like washing machines, LED drivers, and IT equipment. ## Derating and ambient temperature Rated 6 A at 30 °C ambient, the continuous current must be derated as panel temperature rises: 5.64 A at 40 °C, 5.46 A at 45 °C, 5.28 A at 50 °C, 5.04 A at 55 °C, 4.86 A at 60 °C, 4.62 A at 65 °C, and 4.44 A at 70 °C. Mountable in any position, with supply feed from either top or bottom — no mandatory orientation, which simplifies layout in crowded enclosures. Listed as current production.","metaTitle":"Siemens SENTRON 5SV1616-7KK06 RCBO, 6A C-curve, 300mA Type A","metaDescription":"Siemens SENTRON 5SV1616-7KK06 RCBO, 1P+N, 6A rated, C tripping characteristic, 300mA residual current Type A, 6kA breaking capacity per EN 60898. Current production. Sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"77 mm","Width":"18 mm","title":"5SV1616-7KK06","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","description":"RCBO compact 1P+N 6 kA type A 300 mA C6","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Mounting Position":"any","at AC rated value":"6 A","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Operating Frequency":"50 Hz","Product Designation":"RCBO","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","Weight With Packaging":"133 g","at 30 °C rated value":"6 A","at 40 °C rated value":"5.64 A","at 45 °C rated value":"5.46 A","at 50 °C rated value":"5.28 A","at 55 °C rated value":"5.04 A","at 60 °C rated value":"4.86 A","at 65 °C rated value":"4.62 A","at 70 °C rated value":"4.44 A","Energy Limitation Class":"3","according to EN 61346-2":"F","according to IEC 81346-2":"F","For Testing Equipment Minimum":"195 V","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Either top or bottom","Tripping Characteristic Class":"C","Number Of Poles With Protection":"1","according to EN 60898 rated value":"6 kA","Tripping Fault Current Rated Value":"300 mA","insulation voltage (Ui) rated value":"253 V","Supply Voltage Frequency Rated Value":"50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","according to IEC 60947-2 rated value":"10 kA","Surge Current Resistance At (8/20) μS":"1 kA","Influence Of The Surrounding Temperature":"Max. 95% humidity","Type Of Voltage Of The Operating Voltage":"AC","Mechanical Service Life (Operating Cycles) Typical":"10 000","for rated value of the current at AC in hot operating state per pole":"0.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aec721310ef05fac2c433250b4945b14.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1027104&mlfb=5SV1616-7KK06"},"ai":{"faq":[{"question":"What is the depth of 5SV1616-7KK06?","answer":"The depth is 77 mm, with an installation depth of 70 mm behind the panel face."},{"question":"What is the width of 5SV1616-7KK06?","answer":"The width is 18 mm, occupying 1 modular unit on a DIN rail."},{"question":"Will 5SV1616-7KK06 drop into a panel specified around 5SY4106-7CV?","answer":"Both are 1-module-wide (18 mm) DIN-rail RCBOs, so the physical footprint is the same — but verify the rated current, trip characteristic, residual current type, and breaking capacity against the panel design before swapping, as those ratings differ between order codes."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV1616-7KK06","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV1616-7KK06 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}