{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3112-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3112-6","canonicalUrl":"https://aoctrl.com/siemens/5SV3112-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3112-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3112-6 RCCB, 2-pole, Type A, 25 A rated current, 10 mA residual sensitivity, 230 V AC, 50 Hz, instantaneous, DIN rail mount.","salesMarkdown":"The Siemens 5SV3112-6 is a SENTRON residual current circuit breaker (RCCB), 2-pole, Type A, rated 25 A with 10 mA residual sensitivity for 230 V AC at 50 Hz. It is an instantaneous-trip device — no intentional short-time delay — so it clears a ground fault as fast as the waveform allows, which matters when coordinating with downstream electronics that can't ride through a delayed trip. The IP20 rating is typical for an enclosed distribution board; the conductors must be connected for the protection to hold. Silicon-free construction suits environments where silicone outgassing can foul contacts or optics. The 10 mA residual rating makes this unit suitable for circuits requiring enhanced protection against electric shock — typically circuits supplying wet-area outlets or medical equipment where the standard 30 mA threshold is too high. Type A detection covers sinusoidal AC residual currents and pulsating DC residuals up to 6 mA, which covers most single-phase rectified loads like switch-mode power supplies and LED drivers. The 0.5 kA rated conditional short-circuit current per IEC 61008-1 is the withstand rating under the standard's test conditions; the 10 kA SCCR is the higher breaking capacity when backed by an appropriate series fuse rated up to 63 A. Supplementary devices can be installed — typically an auxiliary switch or shunt trip for remote indication.","metaTitle":"Siemens 5SV3112-6 SENTRON RCCB, 2-pole, 25 A, 10 mA, Type A,","metaDescription":"Siemens 5SV3112-6 SENTRON RCCB, 2-pole, Type A, 25 A, 10 mA residual, 230 V AC, 50 Hz. Active production. DIN rail mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"100 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/457affd665c75d49795811887fc305f9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1502777&mlfb=5SV3112-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SV3112-6/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 5SV3112-6 and how do I get a price?","answer":"The 5SV3112-6 is sourced and quoted to order against an RFQ through independent distribution. Current availability and pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"Will 5SV3112-6 drop into a panel that was specified around 5SU9354-7KK16 without rewiring?","answer":"The 5SV3112-6 and the 5SU9354-7KK16 share the same 36 mm width (2 modular units) and 70 mm installation depth, so the mechanical fit is identical. The 5SU9354-7KK16 is a 1P+N RCBO (overcurrent + residual protection) with a 6 A thermal-magnetic trip, while the 5SV3112-6 is a 2-pole RCCB with no overcurrent protection — the wiring differs because the RCBO requires a neutral connection through its switched pole. They are not drop-in replacements without circuit redesign."},{"question":"What compliance documentation does this brand provide for 5SV3112-6?","answer":"Siemens SENTRON RCCBs carry CE marking per the Low Voltage Directive and are designed to IEC/EN 61008-1. The silicon-free construction is documented on the declaration. Specific RoHS/REACH declarations are available from Siemens upon request; the product is designed for the European and UK markets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3112-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3112-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}