{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3311-6KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3311-6KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV3311-6KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3311-6KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 2-pole, Type A, In: 16 A, 30 mA, Un AC: 24-125 V, 10 kA SCCR, instantaneous, 2 MW, IP20, DIN rail.","salesMarkdown":"It's designed for AC supply voltages between 24 and 125 V at 50 Hz, and it's instantaneous — no intentional delay, so it clears ground faults as fast as the waveform allows. That 30 mA sensitivity covers personnel protection (hand-to-ground fault path) in circuits where the supply voltage is below the usual 230/400 V range, which is the main reason you'd reach for this specific variant over a standard 230 V RCCB. Depth is 70 mm, height 90 mm — standard SENTRON RCCB footprint, so it drops into any existing SENTRON sub-distribution board without re-drilling the backplate. ## Fault ratings and coordination Short-circuit current rating is 10 kA per IEC 61008-1, with a series fuse maximum permissible of 63 A upstream. The 0.5 kA rated value per IEC 61008-1 is the conditional short-circuit current with the specified series fuse; the 10 kA figure is the rated short-circuit capacity without an external fuse. For selectivity, pair it with a 63 A gG fuse or a 63 A MCB upstream and you get full discrimination up to that level.","metaTitle":"Siemens 5SV3311-6KK13 SENTRON RCCB, 2-pole, 16 A, 30 mA, Typ","metaDescription":"Siemens SENTRON 5SV3311-6KK13 RCCB, 2-pole, Type A, 16 A, 30 mA, 24-125 VAC, 10 kA SCCR. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3311-6KK13","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 16 A, 30 mA, Un AC: 24-125 V","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"Un AC: 24-125 V","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"24 -125 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"24 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5f069fe10c35e0d033e6a10aa31df5a7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=627683&mlfb=5SV3311-6KK13"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SV3311-6KK13?","answer":"Submit an RFQ against this order code. Availability and current pricing are confirmed at quote time through our sourcing desk."},{"question":"What is 5SV3311-6KK13's listed depth?","answer":"70 mm, same as the installation depth. The overall dimensions are 70 mm deep, 36 mm wide (2 MW), and 90 mm high."},{"question":"Will 5SV3311-6KK13 drop into a panel specified around 5SU9354-7KK16 without rewiring?","answer":"Mechanically yes — both are 2-module-wide DIN-rail devices with the same 36 mm width and 70 mm installation depth. Electrically, the 5SU9354-7KK16 is a 1P+N RCBO rated at 230/240 V, while this unit is a 2-pole RCCB rated at 24-125 V. If the panel wiring expects a combined overcurrent and residual device at 230 V, this RCCB alone won't provide overcurrent protection and may not suit the voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3311-6KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3311-6KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}