{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3311-6KL","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3311-6KL","canonicalUrl":"https://aoctrl.com/siemens/5SV3311-6KL","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3311-6KL","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3311-6KL, 2-pole RCCB, type A, 16 A, 30 mA, 230 V AC, 10 kA SCCR, 2 MW, IP20, DIN-rail mount.","salesMarkdown":"The Siemens 5SV3311-6KL is a SENTRON residual current circuit breaker (RCCB), 2-pole, type A, rated 16 A with a 30 mA trip threshold on 230 V AC at 50 Hz. This is an instantaneous-trip RCCB (no intentional short-time delay), so it responds within milliseconds to earth leakage — appropriate for general-purpose shock protection. The silicon-free construction makes it fab-compatible: no outgassing from silicone-based compounds that could contaminate wafer processing environments. Depth is 70 mm, height 90 mm. Installation depth of 70 mm matches the overall depth — no extra clearance needed behind the rail. The N-left variant positions the neutral terminal on the left side of the device, which matters when replacing an existing RCCB in a panel wired for left-side neutral. Verify the busbar or ring-tongue routing before committing the BOM line.","metaTitle":"Siemens 5SV3311-6KL SENTRON RCCB, 2-pole, 16 A, 30 mA, 230 V","metaDescription":"Siemens 5SV3311-6KL SENTRON RCCB, 2-pole, type A, 16 A, 30 mA, 230 V AC, 10 kA SCCR, IP20, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3311-6KL","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 16 A, 30 mA, Un AC: 230 V, N left","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"N left","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230 V","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"0.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$36.83 – $104.43","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3133d778a5c3ce487cafaa5fbf43ae37.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=358753&mlfb=5SV3311-6KL"},"ai":{"faq":[{"question":"What are the key ratings for this RCCB?","answer":"2-pole type A, 16 A rated current, 30 mA residual sensitivity, 230 V AC at 50 Hz, 10 kA SCCR per IEC 61008-1, overvoltage category III, IP20, silicon-free, instantaneous trip."},{"question":"Will the 5SV3311-6KL fit a panel designed for the 5SL4363-7?","answer":"No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) with a 54 mm width and 76 mm depth, while the 5SV3311-6KL is a 2-pole RCCB at 36 mm wide and 70 mm deep. They serve different protection functions (overcurrent vs. earth leakage) and have different footprints; a panel designed for the MCB would need rewiring and possibly a different enclosure cutout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3311-6KL","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3311-6KL when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}