{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3312-6GV01","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3312-6GV01","canonicalUrl":"https://aoctrl.com/siemens/5SV3312-6GV01","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3312-6GV01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 5SV3312-6GV01, 2-pole, 25 A rated, 30 mA trip, Type A, instantaneous, DIN rail mount, 10 kA SCCR.","salesMarkdown":"It's an instantaneous design (no intentional delay), so it clears ground faults as fast as the waveform allows, which matters when you're coordinating downstream with a selective main RCCB or an upstream MCB that needs to hold through a transient. Type A detection means it catches sinusoidal AC residual currents plus pulsed DC (typical from single-phase rectifiers, switched-mode supplies, or variable-speed drives). Rated short-circuit current withstand is 10 kA per IEC 61008-1 and EN 60898; the let-through energy is capped at 58 000 A²·s. Surge-current resistance is 1 kA (8/20 µs wave), which helps it ride through lightning-induced transients without nuisance tripping. The 25 A rating holds across the full ambient range from -25 °C to 55 °C without derating; at 65 °C it derates to 23.3 A, and at 70 °C to 17.6 A. Storage limits are -40 °C to 75 °C. Overvoltage category III — suitable for fixed-installation distribution boards downstream of the utility meter.","metaTitle":"Siemens 5SV3312-6GV01 SENTRON RCCB, 2-pole 25 A 30 mA Type A","metaDescription":"Siemens 5SV3312-6GV01 SENTRON RCCB, 2-pole, 25 A rated, 30 mA trip, Type A, 10 kA SCCR, DIN rail mount. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3312-6GV01","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 25 A, 30 mA, Un AC: 230 V, Bulk packaging 36 units","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"Bulk packaging 36 units","Maximum Permissible":"75 °C","Minimum Permissible":"-40 °C","Operating Frequency":"50 Hz","Product Designation":"RCCB","at AC / rated value":"25 A","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Residual Current Type":"A","I2t value / permissible":"58 000 A²·s","at 40 °C / rated value":"25 A","at 45 °C / rated value":"25 A","at 50 °C / rated value":"25 A","at 55 °C / rated value":"25 A","at 60 °C / rated value":"25 A","at 65 °C / rated value":"23.3 A","at 70 °C / rated value":"17.6 A","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Product Feature / Silicon-Free":"Yes","For Testing Equipment / Minimum":"195 V","Position / Of Power Supply Cord":"top or bottom","Let-Through Current / Permissible":"5 200 kA","according to EN 60898 / rated value":"0.5 kA","Tripping Fault Current / Rated Value":"30 mA","Supply Voltage Frequency / Rated Value":"50 Hz","Surge Current Resistance / Rated Value":"1 kA","according to IEC 61008-1 / rated value":"0.5 kA","Switching Function / Short-Term Delayed":"No","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ae47f785d05b5d1181c047c68767eeb8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=572867&mlfb=5SV3312-6GV01"},"ai":{"faq":[{"question":"Where can I buy 5SV3312-6GV01 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ and we'll get you a firm number."},{"question":"What is 5SV3312-6GV01's depth?","answer":"The installed depth is 70 mm, with a width of 36 mm (2 modular units) and a height of 90 mm."},{"question":"What compliance documentation does Siemens provide for 5SV3312-6GV01?","answer":"The RCCB is designed to IEC 61008-1 and EN 60898 standards, with a 10 kA rated short-circuit capacity per those standards. It carries overvoltage category III and IP20 protection. Silicon-free construction is noted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3312-6GV01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3312-6GV01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}