{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3312-6KK13","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3312-6KK13","canonicalUrl":"https://aoctrl.com/siemens/5SV3312-6KK13","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3312-6KK13","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON RCCB, 2-pole type A, In: 25 A, 30 mA, Un AC: 24-125 V, 10 kA SCCR, IP20, DIN rail mount.","salesMarkdown":"It's built for 50 Hz systems and accepts a supply voltage of 24 to 125 V AC — that wide control-voltage range means it plays nice with both 24 V control transformers and 120 V panels without needing a separate coil tap. Mount it in any position — top or bottom feed — which saves headaches when you're retrofitting into a crowded enclosure and the busbar orientation doesn't match the original layout. If you're staring at a 5SL4363-7 MCB on the BOM and wondering whether this RCCB drops into the same slot: different job. They share the SENTRON family and the same 90 mm height and 70 mm installation depth, but the 5SL4363-7 is 54 mm wide (3 width units) versus this part's 36 mm (2 width units). No direct swap — you'd need a different rail footprint and a separate overcurrent device upstream. Maximum permissible series fuse is 63 A.","metaTitle":"Siemens SENTRON 5SV3312-6KK13 RCCB, 25 A, 30 mA, 2-pole","metaDescription":"Siemens SENTRON 5SV3312-6KK13 residual current circuit breaker, 2-pole type A, 25 A, 30 mA, 24-125 V AC, 10 kA SCCR, IP20, active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3312-6KK13","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, type A, In: 25 A, 30 mA, Un AC: 24-125 V","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"Un AC: 24-125 V","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"24 -125 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"24 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"63 A","for rated value of the current at AC in hot operating state per pole":"1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/00603c3bde7d230ff5d142942051474e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=627684&mlfb=5SV3312-6KK13"},"ai":{"faq":[{"question":"Where can I buy 5SV3312-6KK13 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate."},{"question":"When sourcing 5SV3312-6KK13, what's the closest functional second-source — 5SL4363-7?","answer":"The 5SL4363-7 is not a functional second-source for this RCCB. The 5SL4363-7 is a 3-pole miniature circuit breaker (overcurrent protection), while the 5SV3312-6KK13 is a 2-pole residual current device (earth-leakage protection). They serve different protection functions and have different footprints (54 mm vs 36 mm wide)."},{"question":"What is 5SV3312-6KK13's listed depth (70 mm) on this component line?","answer":"The installation depth is 70 mm, matching the overall depth of the device. This fits standard 80 mm deep enclosures with room for wiring."},{"question":"What is 5SV3312-6KK13's listed width (36 mm) on this component line?","answer":"The width is 36 mm, which corresponds to 2 modular width units on a standard DIN-rail grid (60 mm spacing)."},{"question":"Will 5SV3312-6KK13 drop into a panel that was specified around 5SL4363-7 without rewiring?","answer":"No. The 5SL4363-7 is 54 mm wide (3 width units) and is a 3-pole MCB; the 5SV3312-6KK13 is 36 mm wide (2 width units) and a 2-pole RCCB. The footprint, function, and wiring differ — you'd need to rework the busbar and add an overcurrent device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3312-6KK13","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3312-6KK13 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}