{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SV3314-6LA","brand":"Siemens","brandSlug":"siemens","productSlug":"5SV3314-6LA","canonicalUrl":"https://aoctrl.com/siemens/5SV3314-6LA","factsUrl":"https://aoctrl.com/api/mcp/products/5SV3314-6LA","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SV3314-6LA, 2-pole RCCB, Type A, 40 A, 30 mA, 230 V AC, 10 kA SCCR, with thermal overload protection, instantaneous, DIN rail mount.","salesMarkdown":"The Siemens 5SV3314-6LA is a SENTRON residual current circuit breaker (RCCB), 2-pole, Type A, rated 40 A with a 30 mA trip sensitivity, for 230 V AC, 50 Hz systems. It includes thermal overload protection — that's the 'with thermal overload protection' variant, so it combines ground-fault and overcurrent protection in one 2-module-width (36 mm) package. At 36 mm wide (2 modular width units) and 70 mm deep, it fits standard 60 mm grid-spaced enclosures. Top or bottom feed is allowed, which simplifies panel wiring when the busbar arrangement isn't fixed. Type A detection catches sinusoidal AC residual currents plus pulsating DC — covers most modern electronics and single-phase rectified loads. Instantaneous design (no short-time delay) means it trips within milliseconds on a ground fault, which is correct for final-circuit protection but won't coordinate with upstream delayed-type RCCBs if you need selectivity. Mechanical life of 10 000 operating cycles is typical for this class — fine for distribution, not for frequent switching duty.","metaTitle":"Siemens 5SV3314-6LA SENTRON RCCB, 40 A, 30 mA, 2-pole","metaDescription":"Siemens 5SV3314-6LA SENTRON RCCB, 2-pole, Type A, 40 A rated, 30 mA trip, 230 V AC, 10 kA SCCR, with thermal overload protection. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"70 mm","Width":"36 mm","title":"5SV3314-6LA","Height":"90 mm","Maximum":"45 °C","Minimum":"-25 °C","description":"Residual current operated circuit breaker, 2-pole, Type A, In: 40 A, 30 mA, Un AC: 230 V, with thermal overload protection","Grid Spacing":"60 mm","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"DIN rail (REG)","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Product Variations":"With thermal overload protection","Product Designation":"RCCB","protection class IP":"IP20, if the distribution board is installed, with connected conductors","Overvoltage Category":"III","Design Of The Product":"Instantaneous","Product Feature Silicon-Free":"Yes","Short-Circuit Current Rating":"10 kA","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"top or bottom","according to IEC 61008-1 rated value":"0.5 kA","Switching Function Short-Term Delayed":"No","Value Range Of The Operating Frequency":"50 Hz","value range of the supply voltage at AC":"230 V","Ambient Temperature During Storage Minimum":"-40 °C","Value Range Of The Supply Voltage Frequency":"50 Hz","Supply Voltage For Testing Equipment Minimum":"195 V","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","Short-Circuit Current Of Series Fuse Maximum Permissible":"80 A","for rated value of the current at AC in hot operating state per pole":"1.5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1890b95896eca96ea372a10606c45843.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=555551&mlfb=5SV3314-6LA"},"ai":{"faq":[{"question":"Where can I buy 5SV3314-6LA?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here."},{"question":"What compliance documentation is available for 5SV3314-6LA?","answer":"As a SENTRON device designed to IEC 61008-1, the manufacturer provides CE declaration of conformity and RoHS/REACH compliance documentation. The 10 kA SCCR is rated per IEC 61008-1. For specific UL or CSA listings, verify with the order code — this variant is primarily IEC-marketed for European and global installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SV3314-6LA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SV3314-6LA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}